2.3 SAFETY FACTORS
breaking load limit and the
maximum safe working load limit (SWLL). In this
case, the breaking load limit of each of the flying
points is 4,000 kg (8,820 lbs) as determined by
destructive testing in independent laboratories. With
a 10:1 safety factor, a total amount of 1,600 kg (3,527
lbs) can be flown from the 4 flying points. Each flying
point has a capacity of 400 kg (882 lbs) with a 10:1
safety factor.
The safety factor is defined as the
coefficient between the
T
The use of two hoists with a load capacity as
expressed on the previous page is mandatory. It
should be kept in mind that at certain moments, the
complete load may be supported by only one of the
hoists.
he maximum number of AERO-38 units
that can be suspended from the AX-AERO48 flying
grid is 20 (with 10:1 safety factor). T
The
maximum limits established by the manufacturer
should never be exceeded.
This is why the load capacity of the individual
hoist must be superior to the weight of the array
column.
NOTE: The rigging systems of the AERO-38 and the
AERO-48 are compatible. Some accessories (AX-
AERO38, AX-AERO48) can be used by both systems.
he maximum
number of AERO-182 units that can be suspended
from the AX-AERO48 flying grid is 16 (10:1).
Aero-38
Manual del usuario/
User´s manual
48
4 x 400Kg (10:1)
3.1 AERO-38A
3. SELF-POWERED SYSTEMS
The Aero-38A is a three way, class D, self
powered system.
Nominal amplifier power (RMS) per way:
LF:1000W MF: 500W HF:500W
Amplifier panel description:
A)
: A
B)
:
C)
:
E)
.
F1)
:
F2)
:
6
(at 230V)
G)
:
1=GND (ground)
2=(+) Non inverted input
3=(-) Inverted input
H)
:
LIMIT
SIGNAL
ON
FUSE
AC INPUT
AC OUTPUT
INPUT
LOOP THRU
D)
: Indicates that the amplifier
is under protection mode because damage risk due to
short circuit or extreme working temperature.
PROTECTION
mplifier limiter indicator lights.
When lit, the level of the signal source should be
reduced.
Signal presence indicator at the
amplifiers' inputs.
Indicator light for each amplifier
channel.
With PowerCon NAC 3 FCA
connector. Only when the connector is inserted and
rotated (clicked) into place will the AC turn on. The
connector can be used as a switch, rotating the
connector to or from the locked position will turn the
unit on or off, respectively. Mute the signal feeding the
before turning the unit on or off.
With (white) PowerCon
NAC 3 DFCB connector. This is used as an AC loop
thru so that up to boxes
can be power from
a single AC line.
Balanced signal XLR. Pin
assignments as follows :
Used for paralleling several
units, which will share the same input. The output can
also be used to provide signal for an outboard power
amplifier.
INPUT
Rear panel of the AERO-38A amplifier.
F2-PowerCon NAC 3DFCB
HF
G-Input XLR
E-Fuse
H-Output XLR
F1-PowerCon NAC 3FCA
SIGNAL
MF
LF
ON
PRO
TECTION
D
A A
A
B
ZOOM
H G
F1
E
F2
C