How to Use A/D Converter for S6J3110/ S6J3120 Series
Document No. 002-04457 Rev. *B
9
3.5.1.1 Analog Input Enable Setting
The analog input enable setting uses Analog Input Control Register (ADER). This register is target of the Key Code
Register. (Please refer to the "4.1.1.Key Code Register" of the
“CHAPTER: 12 Bit-A/D Converter” in the S6J3110 /
S6J3120 Series Hardware Manual.) This application note setting is AN14 in the analog input pin.
Figure 5. Analog Input Enable Setting Flow
Analog input pin setting (AN14)
ADER_ADER0=0x00004000
ADER register key code setting
Analog inputs enable setting
End