How to Use A/D Converter for S6J3110/ S6J3120 Series
Document No. 002-04457 Rev. *B
19
Table 2 . Selection for Upper and Lower Thresholds
The range comparison function equips continuous detection function for range comparison result.
The continuous detection function performs continuous detection of range comparison result and reduces noise.
When as many detection states of range comparison result as the count set by the continuous detection count
specification for range comparison (ADRCCS.RCOCD2 to RCOCD0) are continuously detected, the range
comparison interrupt factor flag bit (ADRCIF.RCINT) is set to "1". If range comparison result comes to be "not
detected" even once during continuous detection, the continuous detection measurement is cleared to 0 times and
the measurement is performed again.