CY3677 Evaluation Kit User Guide, Doc. No. 002-12185 Rev. *D
5
Safety Information
The CY3677 Evaluation Kit is intended for use as an evaluation platform for hardware or software in a laboratory environment.
The board is an open system design, which does not include a shielded enclosure, so the board may cause interference to
other electrical or electronic devices in close proximity. In a domestic environment, this product may cause radio interference.
In such cases, the user may be required to take adequate preventive measures. Also, this board should not be used near any
medical equipment or RF devices.
Attaching additional wiring to this product or modifying the product operation from the factory default may affect its
performance and cause interference with other apparatus in the immediate vicinity. If such interference is detected, suitable
mitigating measures should be taken.
The CY3677 Evaluation Kit contains electrostatic discharge (ESD)-sensitive devices. Electrostatic
charges readily accumulate on the human body and any equipment, and can discharge without detection.
Permanent damage may occur on devices subjected to high-energy discharges. Proper ESD precautions
are recommended to avoid performance degradation or loss of functionality. Store unused CY3677
Evaluation Kit boards in the protective shipping package.
General Safety Instructions
ESD Protection
ESD can damage boards and associated components. Cypress recommends that the user perform procedures only at an
ESD workstation. If an ESD workstation is not available, use appropriate ESD protection by wearing an antistatic wrist strap
attached to the chassis ground (any unpainted metal surface) on the board when handling parts.
Handling Boards
The CY3677 Evaluation Kit is sensitive to ESD. Hold the board only by its edges. After removing the board from its box, place
it on a grounded, static-free surface. Use a conductive foam pad if available. Do not slide the board over any surface.
Certification Disclaimer
This kit is intended for demonstration, evaluation, or development purposes only and is not considered by Cypress
Semiconductor to be a finished end-product fit for general consumer use. It generates and can radiate radio frequency energy
and has not been specifically tested for CE certification compliance. Operation of this equipment in other environments may
cause interference with radio communications, in which case users at their own expense will be required to take whatever
measures may be required to correct this interference.