Cypress CY3677 Скачать руководство пользователя страница 41

 

Appendix 

CY3677 Evaluation Kit User Guide, Doc. No. 002-12185 Rev. *D 

41 

B.5.  Bill of Materials 

Table B-1. Bill of Materials 

Item 

Quantity 

Reference 

Value 

Description 

Manufacturer 

Manufacturing Part 

Number 

C6 

0.01 UF 

CAP CER 10000PF 50V 10% X7R 
0603 

Murata Electronics  

GRM188R71H103KA01D 

17 

C7,C9,C11,C27,
C38,C41,C46,C
49,C53,C54,C5
5,C56,C57,C65,
C66,C67,C68 

0.1uF 

CAP CER 0.1UF 50V Y5V 0603 

Yageo 

CC0603ZRY5V9BB104 

C10 

4.7uF 

CAP CER 4.7UF 6.3V X5R 0603 

Murata Electronics 

GRM188R60J475KE19D 

C12,C28 

20nF 

CAP CER 0.02UF 50V X7R 0603 

Samsung Electro-
Mechanics America, 
Inc. 

CL10B203KB8NNNC 

C13 

10pF 

CAP CER 10PF 50V C0G 0603 

TDK Corporation 

C1608C0G1H100C080AA 

C26 

2200pF 

CAP CER 2200PF 50V NP0 0603 

Murata Electronics  

GRM1885C1H222JA01D 

11 

C8,C30,C34,C3
9,C40,C50,C51,
C52,C58,C59,C
69 

1UF 

CAP CER 1UF 25V 10% X5R 0603 

Taiyo Yuden 

TMK107BJ105KA-T 

F1 

PTC 
RESETABLE 
FUSE 

PTC RESETTABLE .50A 15V 1812 

Bourns Inc. 

MF-MSMF050-2 

J2  

VIN 

CONN HEADR BRKWAY .100 
02POS STR 

TE Connectivity AMP 
Connectors 

9-146280-0-02 

10 

J5 

VCM 

CONN HEADR BRKWAY .100 
02POS STR 

TE Connectivity AMP 
Connectors 

9-146280-0-02 

11 

J3 

USB MINI B 

MINI USB RCPT R/A DIP 

TE Connectivity AMP 
Connectors 

1734510-1 

12 

J7,J8,J10,J11 

SMA 

CONN SMA JACK 50 OHM EDGE 
MNT 

Cinch Connectivity 
Solutions Johnson 

142-0701-801 

13 

J1,J13,J14,J15,
J16 

JUMPER 

CONN HEADR BRKWAY .100 
03POS STR 

TE Connectivity AMP 
Connectors 

9-146280-0-03 

14 

LED1  

LED Green 

LED GREEN CLEAR 0805 SMD 

Visual 
Communications 
Company - VCC 

CMD17-21VGC/TR8 

15 

LED2 

LED Amber 

LED AMBER CLEAR 0805 SMD 

Bivar Inc. 

SM0805AC 

16 

L7 

FERRITE CHIP 
600 OHM 1.5A 

FERRITE CHIP 600 OHM 1500MA 
1206 

Murata Electronics 

BLM31PG601SN1L 

17 

R30,R31 

49.9 

RES SMD 49.9 OHM 0.1% 1/10W 
0603 

Panasonic Electronic 
Components 

ERA-3AEB49R9V 

18 

R7, R40 

0 ohm 

RES SMD 0.0 OHM JUMPER 
1/10W (0402pkg) 

Panasonic Electronic 
Components 

ERJ-2GE0R00X 

19 

R1,R211 

560 

RES SMD 560 OHM 5% 1/10W 
0603 

Panasonic Electronic 
Components 

ERJ-3GEYJ561V 

20 

R3 

100K 

RES SMD 100K OHM 5% 1/10W 
0603 

Panasonic Electronic 
Components 

ERJ-3GEYJ104V 

21 

R5 

453 

RES SMD 453 OHM 1% 1/10W 
0603 

Panasonic Electronic 
Components 

ERJ-3EKF4530V 

22 

R6 

127 

RES SMD 127 OHM 1% 1/10W 
0603 

Panasonic Electronic 
Components 

ERJ-3EKF1270V 

Содержание CY3677

Страница 1: ...CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D Cypress Semiconductor 198 Champion Court San Jose CA95134 1709 Phone USA 800 858 1810 Phone Intnl 1 408 943 2600 www cypress com...

Страница 2: ...BILITY AND FITNESS FOR A PARTICULAR PURPOSE To the extent permitted by applicable law Cypress reserves the right to make changes to this document without further notice Cypress does not assume any lia...

Страница 3: ...ption 14 3 3 CY3677 EVK USB Connection 14 3 4 Programming the CY29430 15 3 5 Functional Programming of the CY29430 16 3 5 1 Generating and Programming the Device Configuration Profile 16 3 6 eFuse Pro...

Страница 4: ...x 32 A 1 BCP Script to Disable the Default Power up Profile of CY29430 32 B Appendix 34 B 1 Termination Settings of Differential Clock Outputs 34 B 2 Termination Settings of LVCMOS Clock Output 35 B 3...

Страница 5: ...r ESD precautions are recommended to avoid performance degradation or loss of functionality Store unused CY3677 Evaluation Kit boards in the protective shipping package General Safety Instructions ESD...

Страница 6: ...pplications The differential I O standards supported are LVDS LVPECL High Speed Current Steering Logic HCSL and Current Mode Logic CML The single ended signal supported is LVCMOS The device also suppo...

Страница 7: ...the kit software The Kit Operation chapter describes the major features of the CY3677 Evaluation Kit The Hardware chapter describes the hardware content of the CY3677 Evaluation Kit and the hardware...

Страница 8: ...ibes Cautions or unique functionality of the product 1 6 Acronyms Table 1 2 List of Acronyms used in this Document Acronym Definition BOM Bill of Materials CML Current Mode Logic DNP DNM Do Not Popula...

Страница 9: ...Evaluation Kit Only This executable file installs only the CY3677 EVK contents which include example projects hardware files and user documents This package can be used if all the software prerequisit...

Страница 10: ...stall the CY3677 EVK in a location other than the default and then click Next as shown in Figure 2 2 Note When you click Next the CY3677 EVK installer automatically installs the required software if i...

Страница 11: ...rview 6 Read and accept the End User License Agreement and then click Next When the installation begins a list of packages appears on the Installation page A green check mark appears next to each pack...

Страница 12: ...t 2 4 Uninstall Software You can uninstall the software using one of the following methods Go to Start All Programs Cypress Cypress Update Manager Cypress Update Manager and select the specific softwa...

Страница 13: ...ystal Oscillator TCXO reference input The kit is capable of generating fixed 3 3 V 2 5 V and 1 8 V voltages from a 5 V USB port The on board PSoC 5LP U7 performs the USB to I2 C conversion There is on...

Страница 14: ...lating the J5 jumper shunt The single ended LVCMOS clock does not need any on board termination settings Figure 3 2 illustrates the top view and bottom view of the CY3677 EVK Figure 3 2 CY3677 EVK Top...

Страница 15: ...also contains volatile memory that stores an exact copy of the eFuse at the release of reset at power up The output frequency depends on the configurations in the volatile memory Writing the entire d...

Страница 16: ...ing within the configuration to be programmed 3 5 1 Generating and Programming the Device Configuration Profile The ClockWizard 2 1 is used to generate profiles and to perform functional programming o...

Страница 17: ...ting a Configuration Profile using ClockWizard 2 1 7 Click Results in the navigation pane to view the results at any time after a JEDEC file has been generated for a configuration as shown in Figure 3...

Страница 18: ...e of the ClockWizard 2 1 software Figure 3 8 Programming Configuration Profile using ClockWizard 2 1 9 The CY29430 supports the selections of four frequency profiles for a single configuration The Fre...

Страница 19: ...tive click Large change update The expected output frequency will appear on the oscilloscope Note Large change programming refers to the case where the frequency is changing more than 500 ppm Figure 3...

Страница 20: ...age to the device After the device is eFuse programmed you can only change the output frequency through the following ways Note that these changes will revert after a power cycle Large change programm...

Страница 21: ...e CY29430 device Following are the key features of the CY3677 EVK Powered from a USB port Jumper to configure on board LDO output Jumper to short or isolate external connection for termination setting...

Страница 22: ...the OE input of the CY29430 to enable or disable the clock output Frequency Select Jumpers J14 J15 J14 and J15 are used to set the frequency select bits of CY29430 Crystal On board 114 285 MHz OT3 cry...

Страница 23: ...ists the hardware settings required for power selection CAUTION The J13 selection must match with the software configuration of the supply voltage during functional programming and must be set to 2 5...

Страница 24: ...source for the CY29430 device 4 2 6 TCXO Input Reference The CY29430 device can also be evaluated with external TCXO reference The external reference clock source must be connected to the SMA connect...

Страница 25: ...s R30 and R31 are the on board output termination resistors The termination settings are controlled by the J5 jumper shunt The typical laboratory setup for the evaluation of this kit is shown in Figur...

Страница 26: ...Hardware CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D 26 Figure 4 4 CY3677 EVK Connected to an Oscilloscope...

Страница 27: ...scope termination and type of coupling used during measurement These measurements are done using an 8 GHz oscilloscope SMA cables 50 scope termination and DC coupling Sample example project outputs a...

Страница 28: ...Evaluation Kit User Guide Doc No 002 12185 Rev D 28 Figure 5 1 LVPECL 3 3 V 156 25 MHz Clock Measured with DC Coupling 50 Scope Termination Figure 5 2 HCSL 2 5 V 100 MHz Clock Measured with DC Coupli...

Страница 29: ...luation Kit User Guide Doc No 002 12185 Rev D 29 Figure 5 3 LVDS 2 5 V 50 MHz Clock Measured with DC Coupling 50 Scope Termination Figure 5 4 LVCMOS 1 8 V 26 MHz Clock Measured with DC Coupling 10X Se...

Страница 30: ...mon tab 3 Change VCXO settings from Disable to Enable Select Total Pull Range to 275 ppm and VCXO Gain Polarity to Positive Click the Generate button The settings is shown in Figure 5 5 Figure 5 5 VCX...

Страница 31: ...support web page or e mail at clocks cypress com Note 1 The default 114 285 MHz LVDS profile programmed into the device does not have the OE functionality enabled Hence you cannot control it through...

Страница 32: ...r choice and the extension iic for example myfile iic 2 Write the following set of commands in your iic file w 55 63 00 w 55 63 01 delay 1 w 55 d7 C0 delay 5 w 55 61 00 w 55 61 03 delay 5 w 55 61 00 3...

Страница 33: ...Appendix CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D 33 Figure A 1 BCP Script to Disable the Default Power up Profile of CY29430 4 4 6 7...

Страница 34: ...ion Settings of Differential Clock Outputs The CY29430 device supports four high speed differential I O standards Figure B 1 illustrates industry standard differential termination techniques for refer...

Страница 35: ...nd the receiver Figure B 2 Recommended LVCMOS Termination Scheme for DC AC Measurements 50 Transmitter Receiver VDD VDD RS CL The desired output measurement can be done using an SMA cable connected to...

Страница 36: ...Appendix CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D 36 B 3 Schematics Figure B 3 Block Diagram...

Страница 37: ...Appendix CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D 37 Figure B 4 Power Supply Design and LED Indicators...

Страница 38: ...CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D Figure B 5 Controller Schematics...

Страница 39: ...CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D Figure B 6 CY29430 Schematics...

Страница 40: ...Appendix CY3677 Evaluation Kit User Guide Doc No 002 12185 Rev D 40 B 4 Fabrication Drawing Figure B 7 Fabrication Drawing...

Страница 41: ...s 9 146280 0 02 10 1 J5 VCM CONN HEADR BRKWAY 100 02POS STR TE Connectivity AMP Connectors 9 146280 0 02 11 1 J3 USB MINI B MINI USB RCPT R A DIP TE Connectivity AMP Connectors 1734510 1 12 4 J7 J8 J1...

Страница 42: ...rochip Technology MIC5301YD5 TR 35 1 U10 PUSBM12VX4 TL 115 TVS DIODE 5 5VWM 12VC 6HXSON NXP Semiconductors PUSBM12VX4 TL 115 36 1 Y1 CRYSTAL4 SM CRYSTAL 114 2850MHZ 18PF SMD NDK NX3225SA 114 285MHZ EX...

Страница 43: ...3GEY0R00V 50 2 R216 R225 1k RES SMD 1K OHM 1 1 10W 0603 Panasonic Electronic Components ERJ 3EKF1001V 51 2 R221 R222 2 2K RES SMD 2 2K OHM 5 1 10W 0603 Yageo RC0603JR 072K2L 52 1 R42 0 ohm RES SMD 0 0...

Страница 44: ...n Profile Updated table title for Table 4 4 and Table 4 7 B 08 16 2016 TAVA Updated Introduction Programming the CY29430 and Generating and Programming the Device Configuration Profile Updated Table 4...

Страница 45: ...AD9522 4 PCBZ AD9552PCBZ 125614 HMC850LC3 EKIT01 HMC767LP6CE NBA3N206SDGEVB EV ADF4355 3SD1Z AD9516 1 PCBZ AD9516 4PCBZ AD9520 5PCBZ AD9530 PCBZ AD9547 PCBZ AD9553 PCBZ AD9557PCBZ AD9559 PCBZ LMH2180S...

Отзывы: