Absolute Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the device. User guidelines are not tested.
Operating Temperature
Table 9. Absolute Maximum Ratings
Symbol
Description
Min
Typ
Max
Units
Notes
T
STG
Storage Temperature
-55
25
+100
°C
Higher storage temperatures
reduce data retention time.
Recommended storage
temperature is +25°C ± 25°C.
Extended duration storage
temperatures above 65°C
degrade reliability.
T
A
Ambient Temperature with Power Applied
-40
–
+85
°C
Vdd
Supply Voltage on Vdd Relative to Vss
-0.5
–
+6.0
V
V
IO
DC Input Voltage
Vss - 0.5
–
Vdd + 0.5
V
V
IOZ
DC Voltage Applied to Tri-state
Vss - 0.5
–
Vdd + 0.5
V
I
MIO
Maximum Current into any Port Pin
-25
–
+50
mA
ESD
Electro Static Discharge Voltage
2000
–
–
V
Human Body Model ESD.
LU
Latch-up Current
–
–
200
mA
Table 10. Operating Temperature
Symbol
Description
Min
Typ
Max
Units
Notes
T
A
Ambient Temperature
-40
–
+85
°C
T
J
Junction Temperature
-40
–
+100
°C
The temperature rise from
ambient to junction is package
specific. See
Thermal Imped-
ances by Package
on page 35.
The user must limit the power
consumption to comply with this
requirement.
[+] Feedback