6BCYW20706 Interfaces
CYW920706WCDEVAL Hardware User Guide
Doc. No.: 002-16535 Rev. **
18
shows which of the selectable CYW20706 interfaces are supported on the CYW920706WCDEVAL board.
CYW20706
Pin
Schematic Signal Name
Bonded
GPIOs
Description
Default
State
I/O Type
Signal Function and Notes
A8
I2S_PCM_OUT/P3/P29/P35
I2S_PCM_OUT
LOW
O
I2S_DO/PCM_OUT. To use I
2
S, set SW5-5 to the OFF position, from the SDK you need to configure
the
pcm_config
structure pointer with the mode role set and use the function
wiced_hal_set_pcm_config
to select the I
2
S function. I/Os P3, P29, and P35 must remain disabled.
This pin can be configured as I
2
C SCL by calling
wiced_hal_i2c_init(WICED_I2C_SDA_I2S_DOUT_PCM_OUT_SCL_I2S_DIN_PCM_IN)
which
selects the I2C_SCL on I2S_PCM_OUT.
P3
Floating I/O
This can be used as PUART_CTS by setting SW5-5 to the ON position. It can be monitored at J22-8
if the I
2
S/PCM function is deselected, and I/Os P29 and P35 are disabled.
P29
Floating I/O
No specific function defined. It can be monitored at J22-8 if the I
2
S/PCM function is deselected, and
I/Os P3 and P35 are disabled.
P35
Floating I/O
No specific function defined. It can be monitored at J22-8 if the I
2
S/PCM function is deselected, and
P3 and P29 are I/O disabled. This pin can be configured as I
2
C SDA by calling
wiced_hal_i2c_init(WICED_I2C_SDA_P35_SCL_P37)
which selects the I2C_SDA on P35
B5
BT_GPIO_5/P15
BT_GPIO_5
HIGH
I/O
General Purpose I/O
P15
Floating O
GPIO to monitor battery or general-purpose I/O
B6
BT_GPIO_6/P11/P26
BT_GPIO_6
LOW
I/O
General Purpose I/O
P11
Floating I/O
No specific function defined. It can be monitored at J22-4 if I/O P26 is disabled.
P26
Floating O
LED D10 on/off control that can sink 16 mA and be modulated using the PWM0 circuit on
CYW20706. To use, disable I/O P11.
B7
I2S_PCM_CLK/P2/P28/P37
I2S_PCM_CLK
LOW
O
I2S_CLK. To use, set SW5-1 to the OFF position, select the I
2
S function, and disable I/Os P2, P28,
and P37.
P2
Floating I/O
PUART_RX. To use, set SW5-1 to the ON position, SW5-2 to the OFF position, and
disable I/Os P28 and P37. It can be monitored at J22-5 if the I
2
S/PCM function is deselected with the
mentioned SW5 settings.
P28
Floating I/O
No specific function defined. It can be monitored at J22-5 if the I
2
S/PCM function is deselected, and
I/Os P2 and P37 are disabled.
3
CYW20706 has an internal 40K pull down for LOW state and 40K pull up for HIGH state. If the pin needs to be driven to the opposite HIGH state for an application, one of the other connected
GPIOs should be configured to drive it as needed.