COMMAND
Description and Parameters
set automation event N1 cec A delay N2
Set the delay time that the specified Automation Event must continue
to be true before sending the defined CEC command.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
N2
= 0~240
[Delay seconds]
get automation event N1 cec A delay
Show the delay time for the specified Automation Event’s CEC response.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
set automation event N1 cec A wait N2
Set the length of time to wait after an Automation Event’s CEC response
has been activated before ANY other Automation Event can be
detected.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
N2
= 0~240
[Wait seconds]