49
COMMAND
Description and Parameters
get automation event N1 cec A wait
Show the wait time for the specified Automation Event’s CEC response.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
set automation event N1 cec A command N2
Set the CEC command to send when the specified Automation Event is
activated.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
N2
= {CEC command}
[Comma delimited ASCII hex pairs]
get automation event N1 cec A command
Show the CEC command to be sent when the specified Automation
Event is activated.
set automation event N1 uart A N2
Enable or disable the specified Automation Event’s RS-232 response.
Available values for
N1
:
1 [Power
on]
2
[Output A source active]
3
[Output A source lost]
Available values for
N2
:
OFF
[Disable]
ON
[Enable]