NB:
It is important that the cabinet is at room temperature when calibrating.
______________________________________________________________________________________________________
Door
Avoid opening the door while the drying process is under way as this prolongs the programme
time. When the door is opened, the display shows
-P-
. You have 5 minutes in which to close
the door before the cabinet turns the programme off completely and the cabinet has to be
restarted.
Operation of ECO Sensor drying cabinet
Adjustment of parameters and calibration of sensors
There are ways of optimising the automatic programmes of the drying cabinet for best
possible results.
Adjustments must be made if it is found that:
p
The laundry is not dried sufficiently.
p
The laundry is over-dried – long drying time.
The sensors need to be re-calibrated for ECO+ to work optimally.
Calibrating sensors
To calibrate sensors, turn off the cabinet without any load hung up inside, go to the param-
eter list, choose parameter P400 and set it to the value 1. A calibration cycle will then start
that takes around 5 minutes. When the sensors have been calibrated, the cabinet will re-start
automatically.