Evacuation / Supply air
When the cabinet is on, approx. 95 m³ moist air per hour is evacuated. It must therefore be
ensured that air can enter the room to replace the moist air that is vented out.
Connection to evacuation
The drying cabinet is connected to exhaust air ventilation in accordance with standard.
The drying cabinet can be connected to the evacuation duct in
two ways
, either with a
draft stabiliser or
permanently fitted to a mechanical exhaust vent.
If the drying cabinet is to be connected to an existing vent system, a draft stabiliser must
always be used, so that the general ventilation in the room is not affected.
Permanent fitting must only be carried out when a separate exhaust-air duct is routed to the
drying cabinet, the air flow in the exhaust-air duct being adjusted to 95 m³ per hour.
The drying cabinet has been tested and factory-set for connection with a draft stabiliser.
Air connection on the cabinet
Position and fit the supplied
spigot
(1)
over the hole on the
top of the drying cabinet. Ro-
tate clockwise until the spigot
clicks into place in the slots in
the roof.
Fixing hook in
the spigot
Slot in the roof
for fixing hook