Start a 2 ¼” long wood screw about 3” from each end of the 1” x 2” wood strips (Fig. 7). For metal cabinet, drill ½” 

holes for the 1” x 2” wood strips and the cabinet at the respective locations. 

c.

 

Position the strips on the cabinet bottom and screw the strips securely to the cabinet (Fig. 6). 

d.

 

For a more secure installation, drill four 3/16” holes from inside the cabinet, down into the wood filler strips. Insert 

screws into the starter holes in cabinet and tighten screws until wood filler strips are secured under cabinet. 

 

 

2.

 

Center the hood in place beneath the cabinet 

and flush with the front of the cabinet. 

3.

 

Mark the four keyhole mounting slots for the 

hood. Mark these onto the bottom of the 

cabinet; or, if the cabinet bottom is recessed, 

onto the wood strips. 

4.

 

Mark on the cabinet bottom or wall the 

position of the access hole through which the 

power supply cord is to be routed. 

5.

 

Drill out the electrical power line 

access hole as marked with a 1 ¼” 

wood drill bit (Fig. 8). 

 

 

 

Providing Electrical Power 

6.

 

Screw the four hood mounting wood 

screws into the center of the keyholes 

(Fig. 9) marked on the cabinet bottom 

(for flush installation) or the 1” x 2” 

wood strips (for recessed cabinet 

installation). Do not turn the mounting 

screws in all the way to allow 

adequate space for the hood to be 

fitted into place. 

 

7.

 

Place the range hood on the bottom of the cabinet. Route the power supply cord through the 

access hole and through the knockout. This step will have to be accomplished while 

positioning the hood (Fig. 10). 

8.

 

Fit the four wider ends of the keyholes into the four screws on the cabinet, and then adjust 

the hood until the screws are pushed into the narrow part of the keyhole slots. The front of 

the hood should be flush with the cabinet front.  

9.

 

Check to ensure the rear or top vent is fitted and connected to the duct properly. 

10.

 

Tighten the hood mounting screws all the way into the cabinet or into the 1” x 2” wood strips 

so the hood is firmly attached. 

 

 

Making the Electrical Connection 

11.

 

Secure the electrical connector to the hood with the connector’s “STAR” locknut. 

12.

 

Strip about ½” of insulation from the ends of the electrical power wires. 

13.

 

Connect the power line ground wire to the green ground wire supplied with the hood (Fig. 11) 

14.

 

Connect the black power wire to the black wire supplied with the hood. Do the same with white 

wire. 

15.

 

Reinstall the hood cover plate with the insert screws. 

16.

 

Attach the rectangular and round oil collectors at the far back and under the mesh 

respectively. 

 
Use and Care 

17.

 

Light bulb:  Slide light bulb access cover to expose the lamp-holder. Screw in a light bulb. Do not use round shape light 

bulb for models CY1000 or CY1000R. Do not use more than 60W incandescent light for any model. Recommended use 

of 23W florescent tube which is equivalent to a 90 W incandescent light bulb. 

18.

 

Switches:  The fan and light are each controlled by a rocker switch. The light switch has two positions, “ON” and “OFF”. 

The fan switch has three positions, “HIGH”, “LOW” and “OFF”. 

19.

 

Cleaning:  Clean the hood with a mild detergent suitable for painted surfaces. Do not use abrasive cloth, steel wool pads, 

or scouring powders. 

20.

 

Fan:  The fan assembly is designed such that it will never need lubrication. 

Содержание CY-1000

Страница 1: ...Instructions d installation et d op ration Please read all instructions before installing and operating Veuillez lire toutes les instructions avant l installation et l op ration All wiring must be in...

Страница 2: ...If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified electrician 7 When installed the bottom edge of your Range Hood should be 24 32 above the top of c...

Страница 3: ...use connecting duct 9 The round vent of Cyclone range hoods is 6 in diameter If your round exhaust duct is not 6 in diameter you will need a connecting duct to accommodate the different sizes If your...

Страница 4: ...8 Fit the four wider ends of the keyholes into the four screws on the cabinet and then adjust the hood until the screws are pushed into the narrow part of the keyhole slots The front of the hood shou...

Страница 5: ...nd does not include light bulbs ducts roof caps and other accessories for ducting The warranty does not include normal maintenance and service The warranty does not apply to damages caused by misuse i...

Страница 6: ...Instructions d installation et d op ration Please read all instructions before installing and operating Veuillez lire toutes les instructions avant l installation et l op ration All wiring must be in...

Страница 7: ...de la surface de cuisson 8 Maintenez toujours le conduit clair afin d avoir une circulation d air appropri e 9 Pour r duire le risque d incendie et de d charge lectrique et vacuer d air correctement l...

Страница 8: ...ous n avez pas de conduit d vacuation allant en dehors de votre maison vous devez en faire un S il vous plait consultez ou engagez un professionnel pour effectuer le travail correctement En g n ral po...

Страница 9: ...r est adapt e et reli e au conduit correctement 10 Serrez les vis de support de hotte au maximum dans le cabinet ou dans les bandes en bois de 1 x de 2 ainsi la hotte est fermement attach e tablir la...

Страница 10: ...t n inclut pas les ampoules les conduits les chapeaux de toit et d autres accessoires pour la canalisation La garantie n inclus pas l entretien et le service normaux La garantie ne s applique pas aux...

Страница 11: ...stique 2 25 Switch Left Commutateur Gauche 1 26 Switch Right Commutateur Droite 1 27 Lamp switch Commutateur de lampe 1 28 Name plate Plaque de nom 1 29 Name plate Plaque de nom 1 30 Wiring case Bo te...

Отзывы: