background image

 10

Cybex 18030 Bravo Lift Owner’s Manual

Assembly

Machine Specifications

Total Weight and Size

:

Weight

Machine Dimensions at Rest

Machine Dimensions at Use

747 Lbs

46.69” W x 71.39” L x 83.63” H

Same

339 Kg

118.62 cm W x 181.330 cm L x 212.43 H

Same

The dimensions stated in the installation instructions are the recommended minimum dimensions as 

set forth by the manufacturer. The actual area for access and passage shall be the responsibility of 

the facility and should take into account any required local codes or regulations.

Tools Required

• 

9/16” Wrench

• 

7/32” Allen wrench

• 

1/8”Allen wrench

• 

3/4” Socket or wrench

• 

Hammer

• 

3/16” Pin punch

• 

Loctite

®

 #242

Environment and Storage

Static Electricity

To reduce static electricity increase the humidity. 

Humidity

The unit is designed to function normally in an environment with a relative humidity range of 30% to 

75%. The unit can be shipped and stored in an environment with a relative humidity range of 10% to 

90%.

Temperature

The unit is designed to function normally in an environment with an ambient temperature range of 50° 

F (10° C) to 104° F (40° C). 

Do not install, use, or store the unit in an area of high humidity, such as near a steam room, sauna, 

indoor pool or outdoors. Extensive exposure to water vapor, chlorine and/or bromine could adversely 

affect the equipment.

Содержание Bravo Lift

Страница 1: ...Cybex Bravo Lift Owner s Manual Strength Systems Part Number 18030 999 4 A www cybexintl com...

Страница 2: ...of America 10 Trotter Drive Medway MA 02053 508 533 4300 FAX 508 533 5183 www cybexintl com 18030 999 4 A November 2011 Table of Contents Safety Safety Guidelines And Practices 3 Securing Equipment 6...

Страница 3: ...e of the equipment Read the Owner s Manual carefully before assembling servicing or using the equipment In an institutional environment it is the facility owner s responsibility to properly instruct u...

Страница 4: ...cause severe injury or damage Consult a physician prior to commencing an exercise program If at any time during exercise you feel faint dizzy or experience pain stop and consult your physician Users...

Страница 5: ...a minimum of 500 lbs tensile capacity Cybex recommends 3 8 grade 2 bolts or better If legs frame does not contact surface DO NOT pull down with anchors Shim any leg or frame not in contact with surfa...

Страница 6: ...istance or as defined and required by local building and architectural codes Anchoring of equipment must be completed by a qualified licensed contractor Due to the wide variation of flooring on which...

Страница 7: ...ean upholstery Weekly Inspect all nuts and bolts for looseness Tighten as required Inspect all cables and belts for damage or wear If a cable or belt is worn or damaged immediately discontinue use unt...

Страница 8: ...decals indicate a potentially hazardous situation that could result in minor or moderate injury if the precautions are not observed The diagram following the decals show where each decal is located F...

Страница 9: ...9 Cybex 18030 Bravo Lift Owner s Manual Label Placement 4605 381 X...

Страница 10: ...rench 7 32 Allen wrench 1 8 Allen wrench 3 4 Socket or wrench Hammer 3 16 Pin punch Loctite 242 Environment and Storage Static Electricity To reduce static electricity increase the humidity Humidity T...

Страница 11: ...ENDICULAR OR PARALLEL SHALL BE SO WITHIN 1 REMOVE ALL BURRS BREAK SHARP EDGES 005 010 R SURFACE FINISH INDICATED PER ANSI B46 1 1985 GENERAL MACHINING DIMENSIONS IN INCHES DATE DATE THIS NOTE REFERS T...

Страница 12: ...ired for this procedure 1 Remove the four shipping cones using a 3 4 socket or wrench 2 Attach foot pads to each foot of frame 3 Remove front panel from machine Remove weight stack 1 Verify weight sta...

Страница 13: ...ap and remove 3 Remove lifting post 4 Remove weight plates Move handle pulley and cable 1 Remove the pin spring with a 3 16 punch and hammer securing handle to ball stop and remove handle Pin Spring B...

Страница 14: ...Reattach frame halves and securely tighten the BHSCS and locknuts Securely anchor machine to the floor To maximize stability equipment must be secured to a solid level surface Cybex is not responsibl...

Страница 15: ...ctite on BHSCS and inside threads of ball stop 2 Secure cable to ball stop using a 1 8 Allen wrench 3 Reconnect handle pulley and cable to platform on both sides 4 Position pulley mount parallel to th...

Страница 16: ...ance 2 Adjust handles for desired pulley height 3 Ensure all adjustment knobs are locked into place CAUTION Serious injury can result if precautions are not followed Use equipment only as described in...

Страница 17: ...LEGGED DEADLIFT LUNGE STIFF LEGGED DEADLIFT LUNGE STIFF LEGGED DEADLIFT LUNGE Motions Developed Hip Extension Knee Extension Muscles Used Quadriceps Gluteus Maximus Hamstrings Motions Developed Hip Ex...

Страница 18: ...en servicing Failure to do so could result in personal injury CAUTION Daily Procedures When using strong cleaning agents such as rubbing alcohol or bleach it is advisable to first test in an inconspic...

Страница 19: ...full strength household bleach may be used Allow bleach to puddle on the affected area or apply with a bleached soaked cloth for approximately 30 minutes Dampen a clean soft cloth in water and rinse a...

Страница 20: ...and rinsing Follow up each application with warm water rinse DO NOT use abrasives or high alkaline cleaners DO NOT leave cleaners on for long periods wash immediately DO NOT apply cleaners in direct...

Страница 21: ...belts can fail if not replaced Inspect cables and belts Inspect all cables and belts for wear or damage and proper tension When inspecting cables and belts run fingers on the cable or belt paying part...

Страница 22: ...in belt Belt is necked down narrow section Replace belt if any section is over 1 32 03 narrower than the rest of belt Examine edge of belt both sides Replace belt if any section is narrower than the...

Страница 23: ...nspect bars and handles for wear paying particular attention to tab area connection points Replace all worn handles immediately Inspect snap links for proper latching indicates wear Replace all loose...

Страница 24: ...Nut Rod End Adjustment This type of adjustment uses a socket head cap screw SHCS securing a cable rod end bearing to the machine Primary adjustment is by turning the rod end bearing The other end of...

Страница 25: ...bs in Belt Adjustment Action Loose Belt 1 Using a 7 32 Allen wrench loose set screws 2 Pull belt tight 3 Secure belt in place with set screws 4 Torque set screws to 300 350 lb in 5 Verify that the bel...

Страница 26: ...from 8 30 a m to 6 00 p m Eastern Standard Time For Cybex customers living in the USA contact Cybex Customer Service at 888 462 9239 For Cybex customers living outside the USA contact Cybex Customer S...

Страница 27: ...535 D490 127 D490 128 D490 865 D491 237 D491 238 D497 190 6 033 350 7 727 128 7 717 831 1975 24th Ave SW Owatonna MN 55060 1 888 462 9239 Made in U S A MODEL 8810 90 SERIAL XXXXXXXXXXXXX 125 FINISH MA...

Страница 28: ...the description of the problem the serial number of the equipment and the name and address of the owner in the package along with the part s Merchandise returned without an RMA number on the outside o...

Страница 29: ......

Страница 30: ...10 Trotter Drive Medway MA 02053 508 533 4300 FAX 508 533 5183 www cybexintl com techhelp cybexintl com...

Отзывы: