Cybex Arc Trainer 610A Service Manual
Service
Page 4-23
5.
Remove the crank covers.
A.
Using a Phillips head screwdriver, remove the three screws securing each crank cover in place.
See Figure 6.
B.
Remove both crank covers.
! WARNING: Failure to release the drive belt tension may cause personal injury and may
damage the unit.
6.
Release the drive belt tension.
A.
Using a 7/16” socket wrench, loosen the two screws on the lower pivot shaft until the screws
are raised 1/2” above the shaft. See Figure 15.
NOTE:
The drive belt tension is now released.
7.
Remove the crank arm disk supports.
A.
Using a Phillips head screwdriver, remove the one
screw securing each crank arm disk support in place.
See Figure 20.
! WARNING: Do not touch components on the lower
board. A charge can remain after unplugging
the power cord and turning off the unit.
8.
Remove the lower board assembly.
A.
Pull out on the lower board shield.
NOTE:
It will
snap out.
B.
Disconnect the elevation cable from the lower board.
C.
Using a 3/8” nutdriver, remove the nut, washer and
ground wire from the stud above the lower board.
D.
Using a Phillips head screwdriver, remove the top two screws from the lower board assembly
and loosen the bottom two screws.
E.
Slide the lower board assembly left and off the two bottom screws then gently suspend it by
the cables.
9.
Remove the crank arms.
A.
Using a 7/16” socket wrench, loosen but do not remove the one screw on each crank arm.
See Figure 21.
B.
Remove the crank arms.
Figure 20
Crank Arm Disk
Support (2)
Screw