Cybex Arc Trainer 610A Service Manual
Service
Page 4-17
1.
Elevate the unit and disconnect the power source.
A.
Plug the power cord into the power outlet.
B.
Enter
Test Mode
.
C.
Elevate the unit to a minimum of level 7 incline.
D.
While the unit is elevated, turn the main power switch to the off (O) position and unplug the
power cord from the power outlet.
2.
Remove the access cover.
A.
Using a Phillips head screwdriver, remove the four screws securing the access cover.
See Figure 2.
B.
Remove the access cover.
! WARNING: Flywheel may be hot. Wait until it cools before servicing.
3.
Detach the connecting rods.
A.
Using a 3/16” Allen wrench, remove the screw securing each connecting rod to each crank.
See Figure 4.
NOTE:
Detach only the ends where the rods connect to the crank.
B.
Place a cloth on the frame where each connecting rod will rest.
C.
Rest each rod on a cloth to prevent scratches. See Figure 4.
4.
Remove the side covers.
A.
Using a Phillips head screwdriver, remove the six screws and six washers securing each side
cover in place. See Figure 5.
B.
Remove both side covers.
NOTE:
The gasket will come off with one of the side covers.
See Figure 5.
5.
Remove the center cover.
A.
Using a Phillips head screwdriver, remove the two screws securing the center cover in place.
B.
Remove the center cover.
! WARNING: Do not touch components on the lower board. A charge can remain after
unplugging the power cord and turning off the unit.
6.
Disconnect the elevation cable.
A.
Pull out on the lower board shield.
NOTE:
It will snap out.
B.
Disconnect the elevation cable from the lower board and slide it out of its slot on the frame.