Warning / Error / Fault List Table

 

 

14 

 

Warning table 

 

W00 

Solar input voltage low

 

W04 

Solar input voltage high 

 
 
 

Error table: 

 

E00 

No Grid

 

E01 

AC  frequency  high  (According  to 

code setting table) 

E02 

AC  frequency  low  (According  to 

code setting table) 

E03 

AC voltage high (According to code 

setting table) 

E04 

AC  voltage  low  (According  to  code 

setting table) 

 

 

Fault table   

(Usually  you  need  to  call  service  people  if 
there is always fault condition happened) 

 

F01 

Hardware DC injection of output 

current  (According  to  code 

setting table)

 

F05 

Temperature sensor 1 low 

F06 

Temperature sensor 1 high 

F07 

Hardware temperature sensor 1 

failure 

F08 

Temperature sensor 2 high 

F09 

Hardware temperature sensor 2 

failure 

F10 

Temperature sensor 3 high 

F11 

Hardware temperature sensor 3 

failure 

F15 

Hardware  main  DSP  ADC1 

failure 

F16 

Hardware  main  DSP  ADC2 

failure 

F17 

Hardware  main  DSP  ADC3 

failure 

F18 

Hardware  main  DSP  ADC4 

failure 

F19 

Hardware 

redundant 

MCU 

ADC1 failure 

F20 

Hardware efficiency failure 

F22 

Hardware 

communication 

failure 

F23 

Hardware 

communication 

failure 

F24 

Residual 

current 

failure 

(According  to  code  setting 

table) 

F25 

Hardware RCMU failure 

F26 

Input insulation failure 

F28 

Hardware relay short 

F29 

Hardware relay open 

F31 

Hardware DC Bus 1 OVP 

F33 

Hardware DC Bus 2 OVP 

F36 

AC output current high (fast) 

F37 

AC output current high (slow) 

F42 

Hardware CT failure 

F45 

Hardware AC current OCP 

F60 

DC input current high (slow) 

F70 

DC input current high (fast) 

Содержание CPSPV4000ETL

Страница 1: ...User s Manual CPSPV5000ETL CPSPV4000ETL CyberPower Systems Inc www cpsww com...

Страница 2: ...g all source of power CAUTION The Inverter must be connected to an equipment grounding conductor directly or via the AC ground ATTENTIO Risk of burning During operation the case temperature may exceed...

Страница 3: ...Copyright 2012 CyberPower Systems Inc UNPACKING 2 1 CPSPV5000ETL or CPSPV4000ETL module 2 Stainless wall mount bracket 3 User s manual 4 Warranty card 5 Self tapping screws M6 30L 5...

Страница 4: ...ts Routing the wires Ensure that you have obtained all permits required by local authorities or utilities before commencing installation Inverter Location WARNING Burn hazard Do not install in a locat...

Страница 5: ...cts of array voltages outside of the MPPT operational window are shown in below Table Voltage Vdc Effect of Array Voltage Inverter Mode 250 Will shut down Shutdown 250 310 Maximum harvest of solar ene...

Страница 6: ...e wires Preparing for the Installation Ensure your local utility is consulted for any requirements for connecting to or returning power to the grid Obtain all permits necessary to complete the install...

Страница 7: ...tached screws Self tapping screws M6 20L 5pcs Step2 Put the inverter on the wall mount bracket Step3 Make sure the host of inverter on the incision of the wall mount bracket Step4 Move the inverter fr...

Страница 8: ...e LED indicator lights providing status ground fault and other warning indication Front Panel Feature 1 LCD Graphic liquid crystal display 160 128 dots 2 Button A Up key select the display item B Down...

Страница 9: ...Recommended type PV KST4 2 5I with 1 5 2 5mm 2 cable double isolation 3 Solar input positive DC wires connect to solar array positive Recommended type PV KBT4 2 5I with 1 5 2 5mm 2 cable double isolat...

Страница 10: ...ration and periodically through its life as required by the utilities This test ensures that inverter dose not send electricity to the utility grid when local utility has shut off the grid for repairs...

Страница 11: ...y 14 59 24 After you select above three items the display will enter into Home Page 1 Home page 5 4 3 2 2 788 1 Pac kW k W 6 12 18 24 E T o t a l 9 2 4 9 9 k W h 1 9 8 7 k W h E D a y 1 3 0 1 2 0 1 2...

Страница 12: ...2 2 Multi meter In Main Menu select Data Logger then press Enter key 2 3 Data Logger Data Logger Daily Log Monthly Log Yearly Log In Data Logger select Daily Log then press Enter key 2 3 1 Daily Log k...

Страница 13: ...0 1 2 0 1 2 1 1 0 5 1 G r i d Q u a l i t y 2 5 1 1 2 0 1 1 0 8 1 2 1 A C V o l t L o w IMPORTANT There are over last 100 dated failure reports on the NS protection can be read In Main Menu select Co...

Страница 14: ...C P L 0 5 K 0 1 0 0 0 1 1 3 Device Info Firmware C Firmware M 3 Runtime Hour V 0 0 1 7 Firmware R V 0 0 5 1 V 0 0 2 5 2 3 Device Info 0 0 1 RS485ID 3 3 In Config select Installer Code then press Ente...

Страница 15: ...or 1 failure F08 Temperature sensor 2 high F09 Hardware temperature sensor 2 failure F10 Temperature sensor 3 high F11 Hardware temperature sensor 3 failure F15 Hardware main DSP ADC1 failure F16 Hard...

Страница 16: ...000 Watt For VDE AR N 4105 4600 Watt Grid Single phase Grid rating voltage 230 Vac Grid voltage range Over under voltage disconnect 180 270 Vac According to code setting table Over under voltage disco...

Страница 17: ...power Firmware revision Inverter ID RTC Real time counter 10 years life Data storage Accumulate historical energy Regulatory Safety IEC 62109 1 2 Grid interface VDE AR N 4105 VDE0126 1 1 A1 UTE C 15...

Страница 18: ...gerous electrical voltage Energy storage timed discharge with 1 minutes Beware of hot surface Observe enclosed documentation There are special requirements The inverter complies with the requirements...

Страница 19: ...tage low ON Fast 197 8 189 189 192 Frequency high OFF Hz 51 50 0 08 sec 50 2 0 2 sec 50 2 0 2 sec 60 3 0 2 sec Frequency high ON Hz 50 05 50 15 50 15 60 1 Frequency low OFF Hz 47 50 0 08 sec 47 5 0 2...

Страница 20: ...opyright 2012 CyberPower Systems Inc Code setting table 19 Reactive power measurement 1 00 0 98 0 98 0 96 0 94 0 92 0 90 0 96 0 94 0 92 0 90 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 P Pemax Cos ind cap...

Отзывы: