Setting Up the V2 Paging Server
Configuring the V2 Paging Server
CyberData Corporation
930367H
Operations Guide
24
2. On the
Nightringer Configuration
page, enter values for the parameters indicated
in
Table 2-9
.
3. After changing the parameters, click on the
Save
button.
4. Click
Reboot
for the new settings to take effect.
Table 2-9. Nightringer Configuration Parameters
Web Page Item
Description
Enable Nightringer
When the nightringer is enabled, the unit will attempt to
register a second extension with the SIP server. Any calls
made to this extension will play a ringtone.
Nightringer Settings
SIP Server
Type the SIP server represented as either a numeric IP
address in dotted decimal notation.
Remote SIP Port
Type the Remote SIP Port number (default 5060)
(8 character limit).
Local SIP Port
Type the Local SIP Port number (default 5061)
(8 character limit).
Note
: This value cannot be the same as the
Local SIP Port
found on the
SIP Configuration Page
.
User ID
Type the
User ID
(up to 64 alphanumeric characters).
Authenticate ID
Type the
Authenticate ID
(up to 64 alphanumeric
characters).
Authenticate Password
Type the
Authenticate Password
(up to 64 alphanumeric
characters).
Re-registration Interval (in seconds)
Type the SIP Registration lease time in seconds (default is
60 minutes) (8 character limit). Re-registration Interval (in
seconds)
Relay Rings to Multicast
When selected, a user-defined audio file is sent to the
specified multicast address and port when the night ringer is
activated.
Multicast Address
Type the Multicast address.
Multicast Port
Type the Multicast port number.
Click the
Save
button to save your configuration settings.
Note
: You need to reboot for changes to take effect.
Click on the
Reboot
button to reboot the system.