7. Specifications
7.1.
Line side characteristics
Mode
Switched network 2-wire leased line
4-wire leased line
Receiver sensitivity
- 43 dBm
- 33 dBm
- 26 dBm
Carrier
detection:
Open threshold
< - 48 dBm
< - 38 dBm
< - 31 dBm
Close threshold
> - 43 dBm
> - 33 dBm
> -26 dBm
Transmission
level:
Nominal
- 10 dBm
- 14 dBm
- 14 dBm
Maximum
- 8 dBm
0 dBm
0 dBm
Minimum
- 16 dBm
- 16 dBm
- 16 dBm
AJ2885P (except FTV model) provides transmit levels higher than –10 dBm : it is under user’s
responsibility to avoid these levels on the public network, and use them on private lines only for
special applications. Maximum received level is –10 dBm only : some higher received level may
induce a loss of performance.
Recom-
mendations
Call/Answer
Speed Bps Xmit 0
Xmit 1
Received 0 Received 1
V22
bis
Call
2400
1200 1200 2400
2400
Answer
2400
2400 2400 1200
1200
V22
Call
1200
1200 1200 2400
2400
Answer
1200
2400 2400 1200
1200
V21 Call 300 1180
980
1850
1650
Answer
300
1850 1650 1180
980
V23
Call
75
450 390 2100
1300
Answer
1200
2100 1300 450
390
V32
9600
1800
Hz
V32 bis
14400
1800 Hz
V34
33600
Adaptive
7.2.
Automatic call & answer
7.2.1. Originating
Automatic dialling or calling by the originating modem is initiated by:
•
"AT" or V25bis commands
•
Push button on front panel
•
DTR 108/1 being enabled
•
Pulse or tone dialing.
Tone recognition occurs when there is:
•
A dial request (public network or private exchange).
•