P.O. Box 749 Peekskill, NY 10566 TEL: (845)737-7009 Fax: (845)737-0426 Web: www.compuvideosystems.com
CLTS-8
To remove the termination from an input to the CLTS-8 sequential switcher please take the following steps:
1) Determine the input to be unterminated by using the diagram in figure 1.
2) Cut the 75 ohm resistor on both sides and remove it. If more than one input is to be unterminated cut the
additional resistors out.
3) Re-install the cover and replace the screws.
4) Reconnect the power supply.
1
2
3
4
5
6
7
8