Page 23 of 42
12.2 Spare Part Installation Procedure
Step 1: Turn off the appliance and allow it to cool.
Step 2: Turn off the gas supply stop tap.
Step 3: Remove the front shelf and left hand support bracket.
Step 4: Making a note of their positions, remove the Stop Button, Charge Socket and
IR Receiver from the right hand shelf and thread through the aperture in the
burner tray.
Step 5: Turn off the appliance stop tap.
Step 6: Disconnect the gas inlet pipe from appliance stop tap.
Step 7: Remove the four burner fixing screws.
Step 8: Remove the burner from the enclosure.
Step 9a: Remote Valve - Remove the three brass nuts from the valve body, remove
the two nuts from the valve base, replace the valve. NOTE: If changing the
Remote Control Valve the high setting is pre-set however the low setting
must be done once the valve has been changed. This can be done by using
the screw on the valve and the plug capped with suitable sealer. Failure to
do this will result in no low setting.
Step 9b: Injectors - For each injector, remove the two injector holder screws and
injector nuts, replace the injector.
Step 9c: Pilot - Remove the brass gas supply nut, unplug the ignition lead from the
pilot, unplug the communication lead from the remote control unit, remove
the two fixing screws, replace the pilot.
Step 10: Re-assemble in the reverse order, reconnect the gas supply.
Step 11: Using a soft brush or vacuum cleaner remove any debris from the top surface
of the appliance.
Step 12: Check for gas soundness.
Step 13: Check that any purpose provided ventilation is free from obstruction.
Step 14: Re-commission the appliance as described in ‘Appliance Commissioning
Instructions’.