8.2 Using the Manual Control Panel. [if fitted]
When fitting please ensure the cable does not become detached from the
membrane. The membrane has a self adhesive pad which can be stuck to the wall.
•
Button #1 - By pressing this switch, this starts the ignition
sequence (press & hold for 3 sec minimum). The gas to the
pilot is open and the magnet unit pressed by the motor, the
spark is generated. When the pilot flame presence is
detected the system holds for 10 seconds to warm the
thermocouple.
•
Once the thermocouple is warm enough to hold the magnet
unit the valve will allow gas to the burner at the maximum
setting.
•
In case of failure during pilot ignition sequence, the EDB
puts the system in safe mode. To restart the ignition
sequence press Button #1 again.
•
It is possible once the fire is lit to operate in standby mode
with pilot only lit. To do this press button #2.
•
By pressing Button #3 the burner flame is increased to the
maximum rate.
•
By pressing Button #4 the burner flame can be reduced to
the minimum rate. This may involve pressing the switch a
number of times in steps to get the lowest setting.
•
To turn the appliance OFF Button #1 is pressed.
•
Each time a button is pressed a “beep” will be heard.
If the appliance is shut down unexpectedly the valve must be
reset first before the fire can be re-lit. To do this press the
“OFF” button until a beep is heard. Then commence the
starting sequence as detailed above by pressing both left had
buttons at the same time.
The pilot is a safety device which monitors the gas pressure and
flue conditions. If a fault in either of these areas are detected
the pilot will not allow the fire to be lit. Please review the
installation conditions before proceeding.