Stability Testing
The HB-P830CE has been stability tested to standards EN280 or AS 14180. The most adverse stability
test is the stationary, lateral slope configuration for both units. The overturning moment created by the
test loads and forces is equivalent to a test on an unloaded machine on a level surface, as shown in the
figure below. For the HB-P830, the test weight/pull force is 22.8 kg /50 lb.
Figure 1: Stability Testing, Equivalent
Part# SUPO-633E
REV C
Page 6 of 34
Safety Guidelines
Maintenance Lock
The maintenance lock must be placed into position whenever the machine is being serviced in the raised
or partially raised position. Serious injury and/or death could result if maintenance lock is not used
properly.
Figure 2: Maintenance Lock Pin Use
Figure 3: Maintenance Lock Pin Storage
Maintenance
WARNING
FAILURE TO COMPLY WITH THE LISTED SAFETY PRECAUTIONS MAY
RESULT IN MACHINE DAMAGE, PERSONNEL INJURY OR DEATH.
x
Never work under an elevated platform until maintenance locks have been engaged.
x
Remove all rings, watches, and jewelry when performing any maintenance.
x
Do not wear long hair unrestrained or loose fitting clothing and neckties which may
become caught on or entangled in equipment.
x
Observe and obey all warnings and cautions on machine and in manual.
x
Keep oil, grease, water, etc. wiped from standing surfaces and handholds.
x
Before making any adjustments, lubricating or performing any other maintenance, shut
off all power controls.
x
Battery should always be disconnected during replacement of electrical components.
x
Keep all support equipment and attachments stowed in their proper place.
x
Use only approved nonflammable cleaning solvents.
x
After maintenance, inspect the machine as described for Pre-delivery.
Part# SUPO-633E
REV C
Page 7 of 34