Chapter 5 Specifications
Parvus DuraNET 20-11
Curtiss-Wright
Page 36 of 44
MNL-0656-01 Rev A8
ECO-N/A
Effective: 16 Nov 21
P
HYSICAL
Weight: ~0.5 lbs.
Installation: base flange mount
Connectors: micro-miniature MIL-DTL-38999 like connectors (Glenair 2M series)
Cooling: passive natural convection without forced air or fans; no moving parts
Enclosure/finish: corrosion resistant, aluminum alloy w/ black anodize finish per MIL-A-8625
E
NVIRONMENTAL
S
PECIFICATIONS
E
NVIRONMENTAL
Qualified to MIL-STD-810G and RTCA DO-160G:
Operating temperature: -40° to +85°C / -40° to +185°F (MIL-810G, Methods 501,502)
Storage temperature: -40° to +85°C / -40° to 185°F (MIL-810G, Methods 501,502)
Operating shock: 40g, 11ms, 3 pos/neg per axis, 18 terminal peak sawtooth pulses (MIL-810G,
Method 516)
Crash hazard shock: 75g, 11ms, 2 pos/neg per axis, 12 terminal peak sawtooth pulses (MIL-
810G, Method 516)
Random vibration: 10Hz to 2000Hz, 3 Axes, Jet-Helo-Tracked Vehicle Profile, 3 Axes (MIL-STD-
810G, Method 514)
Humidity: up to 95% RH @ 40C, non-condensing (conformal coated PWBs; qual by analysis)
Water immersion: 1 meter, 30 minutes (MIL-STD-810G, Method 512)
Blowing sand and dust per MIL-STD-810G, Method 501.5 (sealed enclosure; qual by analysis)
Operational altitude: up to 50,000 feet (9,144 meters) - MIL-STD-810G, Method 500
Storage altitude: up to 60,000 feet (18,288 meters) - MIL-STD-810G, Method 500
EMI/EMC
Qualified to MIL-STD-461F and DO-160G:
Conducted Emissions, CE102, Power Leads, 10 KHz to 10MHz, basic curve
Conducted Susceptibility, CS101, Power Leads, 30 Hz to 150 KHz, Curve 2 (28V and below)
Radiated Emissions, RE102, Electric Field, 10 KHz to 18 GHz, Figure RE102-3
Radiated Susceptibility, RS103, Electric Field, 2MHz to 18 GHz, Aircraft External, 200 Volts per
meter