The
Packetization Sink
setting is not yet implemented. When implemented, it could be used for example, where
you have another sink module, such as a memory module, in the chassis capable of recording the packetizer
traffic. Or when transmitting packetizer traffic, using a chapter 7 encoder, and you want to restrict the packetizer to
just that module. Set to
All
the
Packetization Sink
setting puts identical packetizer traffic out of all sinks in the
chassis. Set to
Controller Only
, the packetizer packet is only transmitted out of the AXN/BCU/40x. Set to any
individual slot, packetizer traffic is restricted to transmitting or recording on the module in that slot. It is
recommended the
Packetization Sink
setting is set to
All
.
Configuring iNET-X Packetizers
Packetizer Format currently only supports iNET-X.
For each channel, enter a unique Stream Id. This is any valid Hex value from 0 to FFFFFFFF.