
34 AXN Quick Start Kit User Guide (BK/0045 | 9 Aug. 2021)
3
Linearization URL settings
The Linearization URL setting is required for thermocouple and RTD modes. See
for thermocouple inputs” on page 39
for details.
Junction Compensation Channel, User Compensation URL, and User Compensation Channel are explained in
“Configuring the AXN/ADC/401 for thermocouple inputs” on page 39
.
Balancing analog channels
The AXN/ADC/401 supports fast balancing of analog channels. This is explained in
using Bridge Balancer” on page 67
. The settings for balance, defining the balance target and the balance range is
done in DAS Studio 3 and programmed into the module.
For each channel users must set Balance Options. The choices are:
None – Balance is not allowed on this channel; previously applied balance is removed.
Lock previous – Prevents new balance values from being applied; locks balance correction applied from previous
runs.
Allowed – Balance adjustments may be applied to this channel; overwrites previous adjustment values.
Содержание AXN
Страница 1: ...AXN Quick Start Kit User Guide ...
Страница 2: ......
Страница 18: ...This page is intentionally blank ...
Страница 72: ...This page is intentionally blank ...