Curtis PMC 1297 Manual
80
Preliminary on Verso page is set with right edge at 7 and 7/8,
and the top (as on the Recto page) at 1/4.
HYD THRTL MAX
% of pump throttle movement at which 100% output occurs
HYD THRTL MAP
Throttle map, as % pump motor PWM at half pump throttle
VARIABLE LIFT
Enables variable Lift: on/off
VARIABLE LOWER
Enables variable Lower: on/off
PUMP MAX SPEED
Pump max. speed during Lift, as % armature PWM
NO LOAD SPEED
Pump max. speed in no-load Lift, as % armature PWM
PUMP BDI L/O
Lift lockout when battery S-O-C <20%: on/off
PUMP BDI WRN
Horn beeps at Lift request if battery S-O-C <25%: on/off
HYD INHIBIT
Hydraulic lockout if throttle >25% at interlock: on/off
LOAD HOLD DLY
Delay after Lift/Lower, in seconds
LV CHECK
Lowering valve check: on/off
LV ACCEL
Acceleration rate for lowering valve current, in seconds
LV DECEL
Deceleration rate for lowering valve current, in seconds
LV MIN C/L
Minimum current for lowering valve, in amps
LV MAX C/L
Maximum current for lowering valve, in amps
LV DITHER
I
LVcoil
dither for lowering valve, in % LV maximum current
ADJ HOURS HIGH
Hourmeter preset high byte: 0–151
ADJ HOURS MID
Hourmeter preset middle byte: 0–255
ADJ HOURS LOW
Hourmeter preset low byte: 0–255
SET TOTL HRS
Apply preset values to total hourmeter: on/off
SET TRAC HRS
Apply preset values to traction hourmeter: on/off
SET PUMP HRS
Apply preset values to pump hourmeter: on/off
SRVC TOTL HRS
Total service timer setting, in hours
SRVC TRAC HRS
Traction service timer setting, in hours
SRVC PUMP HRS
Pump service timer setting, in hours
DIS TOTL HRS
Total disable timer setting, in hours
DIS TRAC HRS
Traction disable timer setting, in hours
DIS PUMP HRS
Pump disable timer setting, in hours
TRAC FAULT SPD
Max. drive speed if disable timer expires, as % Max Speed
PUMP FAULT SPD
Max. pump speed if disable timer expires, as % Lift Max Speed
SERVICE TOTL
Reset total service timer: on/off
SERVICE TRAC
Reset traction service timer: on/off
SERVICE PUMP
Reset pump service timer: on/off
FULL VOLTS
Voltage considered 100% state of charge, in volts
EMPTY VOLTS
Voltage considered 0% state of charge, in volts
RESET VOLTS
Voltage at which state of charge resets to 100%, in volts
MUX ENABLE
Multiplexer inputs enabled: on/off
Program Menu,
cont’d
6 — PROGRAMMER MENUS: Program Menu