![Curtis 1297 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/curtis/1297/1297_manual_2699565031.webp)
Curtis PMC 1297 Manual
23
3 — PROGRAMMABLE PARAMETERS
A: TRACTION
(parameters related to the
traction motor and drive system)
Acceleration Parameters
Drive Current Limit, M1–M2
Acceleration Rate, M1–M2
Current Ratio
Boost Enable
Braking Parameters
Braking Current Limit, M1–M2
Brake Rate, M1–M2
Deceleration Rate, M1–M2
Coast Deceleration Rate
Taper Rate
Throttle Deceleration Rate
Interlock Braking Current Limit
Interlock Brake Rate
Interlock Braking Delay
Restraint
Variable Braking
Electromagnetic Brake Type
Electromagnetic Brake Delay
Speed Parameters
Maximum Speed, M1–M2
Creep Speed
High Speed Latch
Interlock Override
Load Compensation
Throttle Parameters
Throttle Type
Throttle Deadband
Throttle Maximum
Throttle Map
Pot Low Check
Field Parameters
Field Minimum
Field Maximum
Field Map Start
Field Map
Field Check
Emergency Reverse Parameters
Emergency Reverse Current Limit
Emergency Reverse Check
Emergency Reverse Acceleration
Emergency Reverse Time Limit
Emergency Reverse Direction Intlk
Other Traction Parameters
Anti-tiedown
HPD
SRO
B: HYDRAULICS
(parameters related to the
pump motor and hydraulics)
Pump Parameters
Pump Current Limit
Pump Max Speed
No Load Pump Current Limit
No Load Pump Speed
Pump Acceleration
Pump Deceleration
Pump Lock C/L
Pump Lock Delay
Pump BDI Lockout
Pump BDI Warning
Hydraulic Inhibit
Valve Parameters
Lowering Valve Maximum Current
Lowering Valve Minimum Current
Lowering Valve Dither %
Lowering Valve Current Acceleration
Lowering Valve Current Deceleration
Load Hold Delay
Lowering Valve Check
Hydraulic Throttle Parameters
Hydraulic Throttle Type
Hydraulic Throttle Deadband
Hydraulic Throttle Maximum
Hydraulic Throttle Map
Variable Lift
Variable Lower
C: SHARED
(parameters related to both
traction and hydraulics)
Contactor and Sequencing
Delay Parameters
Sequencing Delay
Main Contactor Interlock
Main Contactor Open Delay
Main Contactor Diagnostics
Multiplexer Parameter
Multiplexer Enable
Hourmeter Parameters
Adjust Hours High
Adjust Hours Middle
Adjust Hours Low
Set Hours, Total
Set Hours, Traction
Set Hours, Pump
Service Timer Hours, Total
Service Timer Hours, Traction
Service Timer Hours, Pump
Disable Timer Hours, Total
Disable Timer Hours, Traction
Disable Timer Hours, Pump
Traction Fault Speed
Pump Fault Speed
Service Timer Reset, Total
Service Timer Reset, Traction
Service Timer Reset, Pump
BDI Parameters
BDI Reset Volts
BDI Full Volts
BDI Empty Volts
Individual parameters are described in the following text in
the order they are listed on this page. They are listed by the
abbreviated names that are displayed in the programmer’s
Program Menu. Not all of these parameters are displayed on
all controllers; the list for any given controller depends on its
specifications.
For a list of the individual parameters in the order in
which they appear in the Program Menu, see Section 6:
Programmer Menus.
☞