Curtis PMC 1297 Manual
60
3
C
— PROGRAMMABLE SHARED PARAMETERS: Hourmeters
SET TOTL HRS
The
set total hours
parameter is used to apply the preset high, middle, and low
byte values to the total (i.e., KSI on-time) hourmeter. First, adjust the byte values
as desired for the total hourmeter. Then, program the Apply Total Hours
parameter On, which automatically loads the preset values. Once they have been
loaded, the apply hours parameter should be programmed Off.
SET TRAC HRS
The
set traction hours
parameter is used to apply preset high, middle, and low
byte values to the traction hourmeter. First, adjust the byte values as desired for
the traction hourmeter. Then, program the Apply Traction Hours parameter
On, which automatically loads the preset values. Once they have been loaded,
the apply hours parameter should be programmed Off.
SET PUMP HRS
The
set pump hours
parameter is used to apply preset high, middle, and low
byte values to the pump hourmeter. First, adjust the byte values as desired for
the pump hourmeter. Then, program the Apply Pump Hours parameter On,
which automatically loads the preset values. Once they have been loaded, the
apply hours parameter should be programmed Off.
SRVC TOTL HRS
The
total service hours
parameter is used to set the timer for the next scheduled
overall maintenance. The total service timer can be adjusted between 0.0 and
50.0, in 0.1 increments, with 25.0 being equivalent to 2,500 hours (25.0
×
100).
SRVC TRAC HRS
The
traction service hours
parameter is used to set the timer for the next
scheduled traction motor maintenance. The traction service timer can be
adjusted between 0.0 and 50.0, in 0.1 increments, with 25.0 being equivalent
to 2,500 hours (25.0
×
100).
SRVC PUMP HRS
The
pump service hours
parameter is used to set the timer for the next
scheduled pump motor maintenance. The pump service timer can be adjusted
between 0.0 and 50.0, in 0.1 increments, with 25.0 being equivalent to 2,500
hours (25.0
×
100).
Hourmeter Service Timer Setting