5
2 — INSTALLATION & WIRING
J1
Pin 1
Pot Wiper
J1
Pin 2
Pot High
J1
Pin 3
Lift Lockout Output
J1
Pin 4
Mode Switch (
open=M1, closed=M2)
J1
Pin 5
Keyswitch Input (KSI)
J1
Pin 6
Interlock Input
J1
Pin 7
B+
J1
Pin 8
Pot Low
J1
Pin 9
Lift Lockout Input / Pump SRO input
J1
Pin 10
Forward Input
J1
Pin 11
BDI Output (0–5V)
J1
Pin 12
Reverse Input
J1
Pin 13
I/O GND
J1
Pin 14
Emergency Reverse
CONNECTIONS: High Current
Four M4 bolt-on power terminals are provided for the high current connections:
two for the motor
(M1
,
M2)
and two for the battery (
B-
,
B+
). The recommended
assembly torque for the M4 bolts is 1.6±0.2 N.m.
CONNECTIONS: Low Current
The low current logic control connections are provided by a 14-pin connector.
A 4-pin low power connector is provided for the programmer and the charge
inhibit input, and a 2-pin low power connector for the electromagnetic brake.
1
2
3
4
J2
J2
Pin 1
Rx
J2
Pin 2
I/O GND
J2
Pin 3
Tx/charge inhibit
J2
Pin 4
+15V
J3
Pin 1
Brake +
J3
Pin 2
Brake -
1
2
J3
J1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
The mating connectors are:
J1 Molex Mini-Fit-Jr. receptacle p/n 39-01-2140
J2 Molex Mini-Fit-Jr. receptacle p/n 39-01-2040
J3 Molex Mini-Fit-Jr. receptacle p/n 39-01-2020,