27
Remove the injector with a 7 mm spanner and replace the
injector with the ones from the spare set, with corresponding
diameters suitable to the type of gas that is going to be used,
according to the information chart (which is also supplied in the
gas conversion kit).
To Replace the Oven/Grill Injectors
Removal of the Grill Burner Injector
The grill injector can be accessed by removing the single screw
on the tip of the burner (as shown). Remove the screw and pull
the grill burner towards the front of the cooker, the injector will
be revealed on the rear surface of the cavity.
Screw
Removal of the Oven Burner Injector
The Oven Burner Injector is not accessible; to change or service this part, please contact a qualified engineer.
Adjusting the Reduced Flame Position
For the oven burner, operate the oven burner at minimum position for 5 minutes, then open and close the oven
door 2-3 times to check the burner’s flame stability.
Reduced flame position adjustment is not required for grill burners.
The position of the adjustment screw must be loosened (turn
anti-clockwise) for conversion from LPG to NG. For conversion
from NG to LPG, the same screw must be tightened (turn
clockwise). Make sure that the appliance is unplugged from
the electric mains and the gas supply is open.
Adjustment
Screw
Thermostatic oven valve
* All images are for indication only; please refer to your individual unit for actual item.
CFSGWH_SV12_IB_120607_Annie.indd 27
12年6月7日 下午7:15