HOW TO SET TIME CLOCK REGENERATION CONTROL
HOW TO SET DAYS ON WHICH WATER SOFTENER IS
TO REGENERATE:
Rotate the skipper wheel until the number "1" is at the red
pointer. Set the days that regeneration is to occur by sliding
tabs on the skipper wheel outward to expose trip fingers.
Each tab is one day. Finger at red pointer is tonight. Moving
clockwise from the red pointer, extend or retract fingers to
obtain the desired regeneration schedule.
HOW TO SET THE TIME OF DAY:
(1) Press and hold the red button in to disengage the drive
gear.
(2) Turn the large gear until the actual time of day is
opposite the time of day pointer.
(3) Release the red button to again engage the drive gear.
(4) Time of regeneration is preset for 2:00 a.m.
3-3
HOW TO MANUALLY REGENERATE YOUR WATER
SOFTENER AT ANY TIME.
Turn the manual regeneration knob clockwise.
A slight, clockwise movement of the manual regeneration
knob engages the program wheel and starts the regenera-
tion program.
The black center knob will make one revolution in the
following approximately three hours and stop in the position
shown in the drawing (SERVICE POSITION).
Even though it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit
might be set only one-third of this time.
In any event, conditioned water may be drawn after rinse
water stops flowing from the water softener drain line.
Содержание NLS0500
Страница 16: ...CONTROL VALVE 12 DAY TIMER 6 3 ...