HOW TO SET METER REGENERATION CONTROL
(3) Release the red button to again engage the drive gear.
HOW TO MANUALLY REGENERATE YOUR WATER
SOFTENER AT ANY TIME:
A slight, clockwise movement of the manual regeneration
knob engages the program wheel and starts the regenera-
tion process.
The black center knob will make one revolution in the
following approximately three hours and stop in the position
shown in the drawing.
Even though it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit
might be set for only one-third of this time.
In any event, conditioned water may be drawn after rinse
water stops flowing from the water conditioner drain line.
NOTE: The backside of the timer is set the same as the
standard time clock regenerated models.
* Adjusted hardness equals hardness in grains per gallon
(gpg) plust 3 times the iron in parts per million (ppm).
3-4
TYPICAL RESIDENTIAL APPLICATION:
To program, just set the time, set the hardness and it
automatically monitors system needs and regenerates only
when necessary. To set time of day, press red time set
button and turn 24-hour gear until present time of day is
opposite "time of day arrow." Set program wheel by lifting
the "people" dial and rotating it so that the number of people
in the household is aligned with the grains per gallon water
hardness (adjusted hardness*) scale. Release the dial and
check for firm engagement at setting. (This method will
provide reserve capacity of one day's supply based on 75
gallons per person.)
OPTIONAL PROGRAMMING PROCEDURE:
Calculate the gallon capacity of the system, subtract the
necessary one day's reserve requirement and set the gal-
lons available opposite the small white dot on the program
wheel gear. Note: drawing shows 850 gallon setting. The
capacity (gallons) arrow denotes remaining gallons exclu-
sive of fixed reserve.
HOW TO SET THE TIME OF DAY:
(1) Press and hold the red button in to disengage the drive
gear.
(2) Turn the large gear until the actual time of day is
opposite the time of day pointer.