METER INITIATED MODELS:
NOTES:
(1) Dial settings based on this capacity. Consult dealer
before changing salt dosage.
(2) Actual capacity may vary substantially depending on
water analysis and operating conditions. Softening
capacities for systems containing 0.5 and 0.75 cubic
feet are based on SOFTENING PERFORMANCE,
systems containing 1.0 cubic feet and larger are based
on Radium 226/228, Barium and Softening.
(3) For satisfactory performance indicated flow rates and
duration should not be exceeded. Flow rates specified
are adequate for normal residential applications. Do
not use Service Flow Rate when sizing commercial
applications or if treated water is to supply a geothermal
heat pump, swimming pool, etc. (contact dealer before
selecting equipment).
5-2
Maximum operating temperature 100°F (38°C); Electrical requirements 110V/60Hz (220V/50Hz); Operating pressure 20-
125 psi. All types water softener salt may be used (See MAINTENANCE). Specifications subject to change without notice.
ITEM
System Style:
Nominal Media Volume, cu. ft.
Salt dosage, lbs.:
Factory Setting (1)
Maximum Setting
Nominal Softening Capacity,
grains:(2)
At factory salt setting
At maximum salt setting
Operating Flow Rates, gpm: (3)
Continuous (no duration limit)
Service (10 minutes or less)
Pressure Loss @ Operating Flow
Rates, psi:
Continuous
Service
Regeneration Flow Rates, gpm:
Backwash (4)
Brine/Rinse
Rapid Rinse
Brine Refill
Inlet/Outlet Pipe Size, in. (5)
Mineral Tank Diameter x Height, in.
Overall Depth & Height w/Control
Valve, in.
Brine Tank, W x D x H, in.
Approx. Salt Storage, lbs.
Approx. Shipping Weight, lbs.
NSM0751
0.75
6.0
12.0
21,450
22,500
3.0
6.0
6.0
10.0
1.2
0.26
1.2
0.5
3/4 or 1
7 x 44
17 x 51
15x15x34
160
76
NSM1001
1.0
6.0
15.0
18,600
30,000
4.0
7.0
6.0
15.0
1.5
0.33
1.5
0.5
3/4 or 1
8 x 44
17 x 51
15x15x34
160
90
NSM1501
1.5
9.0
24.0
27,900
45,000
6.0
8.0
8.0
15.0
2.4
0.33
2.4
0.5
3/4 or 1
10 x 44
17 x 51
15x15x34
160
117
NSM2501
2.5
15.0
24.0
46,500
60,000
9.0
10.0
11.0
15.0
3.5
0.64
3.5
0.5
3/4 or 1
12 x 54
17 x 61
15x15x34
160
188
NLSM0751
0.75
6.0
12.0
21,450
22,500
3.0
6.0
6.0
10.0
1.5
0.33
1.5
0.5
3/4 or 1
8 x 35
17x 42
15x15x34
160
75
NLSM1001
1.0
6.0
15.0
18,600
30,000
4.0
7.0
6.0
15.0
2.0
0.33
2.0
0.5
3/4 or 1
10 x 35
17 x 42
15x15x34
160
86
NSM2001
2.0
12.0
24.0
37,200
54,000
7.0
8.5
9.0
15.0
2.4
0.33
2.4
0.5
3/4 or 1
10 x 54
17 x 61
15x15x34
160
142
SPACEMAKER
TWO TANK
(4) For system to operate properly, pumping rate of well
pump MUST be sufficient to backwash unit at rate
specified.
(5) Model numbers ending with "1" are 1 in. those ending
with "0" are 3/4 in. Example: NSM1001 becomes
NSM1000.
Содержание NLS0500
Страница 16: ...CONTROL VALVE 12 DAY TIMER 6 3 ...
Страница 18: ...CONTROL VALVE METER INITIATED 6 5 ...