7
The Universal JetScan screen will briefly flash “SAVING;” the following screen then will
appear for 5 seconds.
This screen instructs users to adjust the hopper guides to one of four pre-marked positions.
The hopper guides feature a series of numerical settings which correlate to the width of the
notes.
Thickness Adjustment Dial
This gray dial, located on top of the Universal JetScan, adjusts the tightness of the feeder
through which notes pass during operation.
The dial features a series of numbers, with 0 being center. Negative numbers, such as -1 and
-2, appear to the left of 0. Positive numbers, such as +1 and +2, appear to the right of 0.
Modes of Operation
Universal JetScan has five basic operating modes for processing:
count
,
mixed
,
offsort
,
sort
and
stranger detect
.
Count
This mode counts any document that complies with document-size and density-setting
specifications. This mode only counts pieces; note scanning does not occur.
To avoid an increase in no calls and feed errors, notes must be processed at the
required hopper-guide setting.
For normal feeding, always start at zero.
By turning the thickness adjustment dial to the right and to access negative
numbers, the rollers are made tighter. This might be done when excessive
double or chain errors occur.
By turning the thickness adjustment dial to the left and to access positive
numbers, the rollers are made looser, allowing the notes to flow through the
Universal JetScan easier.
ADJUST HOPPER
TO POSITION 2
© 2014 Cummins-Allison Corp.