18
Condition
Action
Universal JetScan may have
processed two or more notes as
one.
Remove all notes from the pocket indicated on the screen and put them on
the hopper. Press CONT.
If the alarm repeatedly occurs, adjust the gray thickness adjustment dial
on top of the machine behind the hopper extension. Rotate in the negative
( - ) direction as indicated by numbers on front of the dial.
Condition
Action
If Universal JetScan is configured
in SETUP to stop on non-faced
notes, it will stop and display
“FACING ERROR” when a non-
faced note is processed.
Remove the top note in the pocket indicated on the screen, correct its
facing, and put it back in the same pocket. Then press CONT. This will be
added to the appropriate batch (strap), sub-batch, batch and day totals.
Condition
Action
Universal JetScan cannot
recognize the denomination of a
note and has stopped. This “NO
CALL” note is the top note in the
pocket indicated on the screen.
This note has not been included
in the count.
Inspect the top note in the pocket indicated on the screen. Do not remove
all notes from this pocket.
If the note should be counted, keep the note in the same pocket and then
enter its denomination using the correct denomination value key based on
the country that is selected. Universal JetScan will start, and this note will
be added to the count.
The note also may be reprocessed. Place the note in the hopper; press
CONT. Universal JetScan will re-start.
If there is no need to include the no-call note in the current count, remove it
and press CONT. Universal JetScan will re-start. The removed document will
not be added to the count.
Two-Pocket Universal JetScan
®
Note Scanner
All Models