background image

 
 
 
 

CMX02 

 Coin Counter User Guide 

 

 

CUMMINS ALLISON, A CPI BRAND 3350 Ridgeway Drive, Unit 3,

 

Mississauga, Ontario L5L 5Z9 

www.cranepi.com   Tel: 1-800-499-6191   

Setting the Coin Size 

 
Before you start counting, ensure to set both the thickness and diameter dials to the correct 
denomination you are going to count. For alternate denominations or tokens, see Manual Adjustment 
for token counting. 

 

Note: Smaller coins will be rejected but larger coins stay in the machine and may cause jams. 

 

 

 

Diameter adjuster

 

Thickness adjuster

 

 

Manual Adjustment for Token Counting 

 
Thickness 

Open the right top cover. Turn the Thickness adjuster to maximum. Place the token under the thickness 
block and turn the adjuster slowly down until it gently touches the token. Turn the adjuster backward 
until the token moves freely, without resistance, between disc and thickness block. 

 

Thickness 

Thickness 

Diameter 

Diameter 

 

Diameter 

Lift up the transport belt. Turn the Diameter adjuster to maximum. Place the token on the transport track and 
turn the adjuster slowly narrow until it gently touches the token. Turn the adjuster backward until the token 
moves freely and has side clearance of about 0.4 mm. 

Содержание cashMAX CMX02

Страница 1: ...CMX02 User Manual 3350 Ridgeway Drive Unit 3 Mississauga Ontario L5L 5Z9 www cranepi com Tel 1 800 499 6191 Copyright 2022 Cummins Allison ULC ...

Страница 2: ... trademark of SOUTH Automation Group Alterations or any other changes on the product are not allowed without the permission of the manufacturer The warranty applies provided the product has been handled properly for its intended use and in accordance with the user manual Table of Contents Introduction and Intended use 3 Warnings 3 User interface 5 Installation 6 Bag Box installation 7 Setting the ...

Страница 3: ... instructions marked on the product Do not install or use this device outdoors near water or when you are wet Install the product securely on a stable surface See also chapter Installation Never exceed the specified load of the bags as itemized in this manual Failure to do so may result in damage and or user injury Do not touch the coin disc when it is in operation Use best practice Take extra car...

Страница 4: ...www cranepi com Tel 1 800 499 6191 Display Keyboard Right top cover service access Count exit with Quick change switch Coin Hopper Coin disc Coin thickness adjuster Coin diameter adjuster Reject exit Foot pedal connector Printer port RS232 Coin tray support rod Power cord socket main switch Carry handle Coin Hopper ...

Страница 5: ... Selected coin number Number of coins in bag Function keys Denomination in Value mode Key Chart Key Description Normal key stroke 3 seconds key stroke Start Stop Start or stop counting Add to memory Add the count to memory Print Print ticket Batch stop Set batch stop Clear bag content Clear Delete count result and bag content Delete Memory Denomination Select new denomination or coin number Show m...

Страница 6: ...g The main fuse protection must be minimum 1 5A Install the CMX02 where no one can step on it or trip over the line cord and the line cord cannot be damaged The seating area must be stable solid and smooth The bagging unit of the machine must protrude the table edge so that the connected bag hangs freely But ensure the front feet of the CMX02 remain in fully resting on the table work surface Rejec...

Страница 7: ... be attached When using the reject bagging unit the CMX02 must be placed on the left side of the desk so the reject bag hangs freely Warning of possible device tilting Do not exceed the weight of 18 kg about 2000 x 1 coins in the counting bag and 7 kg about 800 x 1 coins in the reject bag Install a support shelf where the bag rest on it if higher weights are in use Connect the reject cup or reject...

Страница 8: ...eter adjuster Thickness adjuster Manual Adjustment for Token Counting Thickness Open the right top cover Turn the Thickness adjuster to maximum Place the token under the thickness block and turn the adjuster slowly down until it gently touches the token Turn the adjuster backward until the token moves freely without resistance between disc and thickness block Thickness Thickness Diameter Diameter ...

Страница 9: ...When the count is finished the CMX01 stops automatically You can also press On Off or push again the coin exit to stop the count manually Piece counting Value counting or It is now possible to RM Print the count M Save the count into the memory C clear the count and bag content C long Clear the count memory of this denomination on Off Count more coins The CMX01 stops with B1 Stop if the pre select...

Страница 10: ...used for counting Memory Add Memory The CMX02 adds automatically full bags to the memory When a count is finished and a bag stop is not reached it is possible to accumulate the count to the memory by pressing M After pressing M the Count Value is reset to 0 M 1 1 1 Show Memory Press the 0 key several times until the total symbol Σ appears Here you can see the sum of all saved counts Press RM Print...

Страница 11: ...00 10000 can be used by pressing B several times B enter new stop M If you change a bag stop and the bag content is not zero there will be a warning message Do you want to clear count and bag Press 1 Yes to clear the two counters or 2 No to count further without clearing Note A steady stop in Batch 1 must be entered in the Settings menu option Denom Batch setting Clear incomplete bag When you inst...

Страница 12: ...h setting 0 1 2 System Setting Currently there are three sub menus available 10 45 Alarm signal On Date Time Factory Default 0 1 2 Alarm signal ON beep always Off no beep Error beep only by error Date Time Enter numbers with numeric keypad and press on Off to save and exit Factory Default Press 2 and confirm with 1 to reset all settings e g denom values and bag stops Screen display Press 2 to swit...

Страница 13: ...he menu as shown here Use the 0 key to move the selection highlighted bar down and use the 1 key to move the highlighted bar left or right to select an item you want to change Press the 2 key to Enter the selected value to change it Press M to set the value or batch to the correct setting Example 0025 for 0 25 coin Press the M to save the value Note if a mistake is made you can press C which will ...

Страница 14: ...ce For optimum performance and error free operation cleaning must be performed regularly The higher the usage the more frequent cleaning maintenance CAUTION Always turn off and unplug the power cord before maintaining the CMX01 Daily cleaning Remove the dirt from the coin track Wipe the dust away under the counting sensor Use a soft brush and a lint free cloth ...

Страница 15: ...ount sensor andremove jammed objects Control the coin diameter setting Enter denom value before There is no value configured for the selected denomination Select another denomination or enter a value in the Denom Batch setting menu Motor does not start w o error message The total memory is selected Select a denomination with the 1 key Please emptythe bag When clearing the count result also the bag...

Страница 16: ...oin counting machine Product type CMX02 Serial number to which this declaration relates is in conformity with the following standards Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Applied harmonized standards EN55022 2010 AC 2011 EN61000 3 2 2014 EN61000 3 3 2013 EN55024 2010 EN60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Date of issue July 2016 Place of issue Mörfelden Walldorf Sign...

Страница 17: ...Up to 3 400 coins per minute Acoustic noise level LpA 79 dB A Uncertainty 2 LpA Standby 1 dB A Chute hopper capacity 1 500 coins Operating temperature 10 C to 35 C 50F 95F Start Stop On Off key Quick change switch Foot pedal Operating humidity 20 to 80 RH non condensing Bag stop 2 levels 0 99 999 coins Individual stop per denom Dimensions Height Depth Width mm with closed chute 190 350 235 Memory ...

Отзывы: