Part No. 4801-5188 Rev 3-2016
Super-Saver XL Heater
– Australian Model
Page
4
of 32
Adjustable
Wrench
Gas Leak Testing
Pipe Glue
¼ in. (7 mm.) Nut Driver
Install screw hooks with hammer or drill.
BE SURE TO CHECK DELIVERY!
Locate packing slip and make sure all
of the listed parts are enclosed. If not,
call your Cumberland Distributor
immediately.
HEATER DIMENSIONS
WEIGHT
60 kG (130 lb.)
HEIGHT
78.8 cm (31 in.)
WIDTH
62.2 cm (24½ in.)
DEPTH
48.9 cm (19¼ in.)
2. Specifications And Requirements
Model No.
Maximum Input
Ventilation
HH-SS-225-XL
65.9 kW (237 MJ/h)
1700 m
3
/h (1000 CFM)
Universal LP Gas:
Maximum 35.0 mbar (3.5 kPa) and minimum 27.5 mbar (2.75 kPa) inlet gas supply
pressure acceptable at heater input. Burner manifold pressure 16 mbar (1.6 kPa) at
maximum input. Gas pressure should be checked by certified gas technician while
heater is in operation. All sealing devices must be restored after the gas conversion.
Natural Gas:
Maximum 50 mbar (5.0 kPa) and minimum 11.3 mbar (1.13 kPa) inlet gas pressure
acceptable at heater input. Burner manifold pressure 6.8 mbar (.68 kPa) at
maximum input. Gas pressure should be checked by a certified gas technician while
heater is in operation. All sealing devices must be restored after the gas conversion.
Gas Inlet
Connection
The installer must attach an installer-supplied flexible gas hose to the factory-
supplied ball valve ½” SAE flare connection.
Refer to heater ratings plate for unit voltage, amperage, and frequency ratings.
READ ALL INSTRUCTIONS BEFORE YOU START ASSEMBLING.
THIS APPLIANCE MUST BE INSTALLED IN FULL COMPLIANCE WITH THE
MANUFACTURERS INSTRUCTIONS, THE AUSTRALIAN GAS INSTALLATION
STANDARD AS/NZS 5601.1 AND ANY LOCAL AUTHORITY REQUIREMENT.
REFER TO AS/NZS 5601.1
FOR PIPE SIZING DETAILS.
MINIMUM CLEARANCES
Measured From
Inches
mm
Ceiling
12
305
Wall
12
305
Floor
20
508
Livestock and combustible materials must not
be allowed to contact heater or come within 3
meters (10 feet) of hot air discharge.