4801-5327 Rev 1-15
Mega-Flow External Damper Fan - Unassembled
Page 16 of 24
7.
Attach the Damper
1.
Install the Damper assembly into cone. The springs that assist the Damper Doors to close are
oriented to the bottom.
2.
Tighten all cone and Damper hardware.
3.
The Damper Ring must be mounted in the holes closest to the orifice on the top, and farthest away from the
orifice in the bottom.
The ring is to be tight. May require ring be tapped into place.
Use
1/4-20 x 1.5" Hex
Head bolts
, lock nuts and washers (provided) to attach ring to cone. Washers go on outside of cone.
See
Figures 14 and 15
.
NOTE:
Check the ring mounting from the side of the
fan. The ring is slanted to allow the force of
gravity to assist in closing the damper doors.
Figure 14:
Side View of Cone
Slanting the ring allows gravity to
assists the doors to shut.
Damper Door Springs are to be
located at the bottom of the cone.
CAUTION:
Fan Ring must be
plumb and level in
order for doors to
operate properly.
NOTE:
Fan Not Shown For
Clarity.
Upper cone ring fits
into inner hole.
NOTE:
Inner hole
will be
capped in a
later step.
NOTE:
Lower cone ring
fits into outer hole.
Figure 13: