32
PNEG-1323
Integra Feed-Link
9. RF Module Option
Possible RF Module Layouts
Figure 9F
The longer the distance between the RF
modules from the tanks to the network
collector, the more important line of sight
becomes. (1 Mile maximum.)
This example shows the bins of each
building networked together as a group and
then wired to an RF module. These RF
modules will send information to the RF
module connected to the network collector.
This example shows all the bins networked
together as a group and then wired to one RF
module. This RF module will send information
to the RF module connected to the
network collector.
This example shows each bin wired to a junction
box. Each junction box is wired to the display unit
inside the building. All the display boxes in a
building are networked together and then wired
to an RF module. Each RF module will send
information to the RF module connected to the
network collector.
This example shows each bin wired to a
junction box and each junction box wired to the
display unit inside the building. All the display
boxes are networked together and then wired
to an RF module. This RF module will send
information to the RF module connected to the
network collector.