20
PNEG-1323
Integra Feed-Link
6. Stand Alone Remote Mounted Display Units
Junction Box
NOTE: If display units are mounted inside, then
you will need a junction box.
1. Remove the multi-hole grommet from the
display unit and exchange it with the
grommet provided with the junction box.
2. Connect the
Red
wire from load cell 1 to the
POWER terminal labeled RED LC1. Repeat
for each consecutive load cell cable.
Connect the RED wire from the 10 conductor
junction cable to the POWER terminal
labeled RED JC.
3. Connect the
Black
wire from load cell 1 to the
GROUND terminal labeled BLACK LC1.
Repeat for each consecutive load cell cable.
Connect the BLACK cable from the 10
conductor junction cable to the GROUND
terminal labeled BLACK JC.
Figure 6A
Junction Box Terminals
4. Connect the
White
wire from load cell 1 to
the left side center SIGNAL terminal labeled
White LC1. Repeat for each consecutive
load cell cable.
5. Connect the remaining wires (up to 8) from
the 10 wire junction cable to the terminals
opposite the already installed
White
SIGNAL load cell wires. Match the wire color
to the corresponding terminal labeled with
the same color. Fasten all wires into
terminals using a flat head screw driver.
Then run junction cable from junction box to
the display box. Junction cable length should
not exceed 100'.
Figure 6B
Always make sure all power is
disconnected and locked out
while any electrical work is
being performed.
NOTE:
Only four (4) load
cell cables shown.