Integra Feed-Link
7. Networking
1. One (1) network cable
a. Disconnect all power sources and run
network cable from display unit to
network collector.
b. Run network cable through water tight
nut and attach to the RS-485-1 terminal.
The A and B connections should match
the color code for the A and B
terminations in the display units on the
network. The ground wire should go in
the terminal labeled “Shield”.
2. Two (2) network cables
a. Disconnect all power sources and run
network cables from display unit to
network collector.
b. Run network cables through the water
tight nuts and attach the first network
cable to the RS-485-1 terminal. Attach
the second network cable to the
RS-485-2 terminal. The A and B
connections should match the color code
for those A and B terminations in the
display units on the network. The ground
wires should go in the terminal
labeled “Shield”.
Figure 7G One (1) Network Cable Connection
Figure 7H Two (2) Network Cable Connections
Figure 7I
White wire “A”
White wire “B”
Ground wire
(Shield)
White wire “A”
White wire “A”
Black wire “B”
Black wire “B”
Shield
terminal
RS-485-1 Terminal for
first network cable
RS-485-2 Terminal for
second network cable
Screw terminal for RS-485
communication. (Socket
pulls out for wiring access.)