Culligan Medallist Plus Sulfur-OX3 Скачать руководство пользователя страница 16

16

01035157 C 10/20

Performance 

Data Sheet

Culligan Medallist Plus® Sulfur-OX3 Filter

Important Notice 

— 

Read this data sheet and compare the capabilities of the unit to your actual water 

treatment needs. Culligan recommends that you have your water supply tested to determine these 

needs before purchasing a water treatment unit.
Culligan knows the more informed you are about your water treatment system, the more confident you 

will be about its performance. It’s because of this and more than seventy years of commitment to our 

customers that Culligan is providing this Performance Data Sheet to its customers.

Manufacturer

 

Culligan International Company 

 

 

9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA 

 

 

1-800-CULLIGAN or 1-847-430-2800 

www.culligan.com

Substance Reduction

This system has been tested according to NSF/ANSI Standard 42 for the reduction of the substances 

listed below. The concentration of the indicated substances in water entering the system was reduced 

to a concentration less than or equal to the permissible limit for water leaving the system, as specified 

in NSF/ANSI Standard 42.
While testing was performed under standard laboratory conditions, actual performance may vary.

Substance

Influent Challenge  

Concentration

Reduction 

Requirement

Average Reduction 

Percentage

Hydrogen Sulfide

1.0 mg/L ± 10%

0.05 mg/L

96.2%

Capacity: 

 

500 gallons

Flow Rate: 

 

4 gpm

Rated Pressure Drop: 

4 gpm @ 2.9 psi

Operating Conditions

Water Pressure Limits: 

20 - 60 psi (140)

Canada:  

 

20 - 90 psi (140 - 620 kpa)

Temperature Limits: 

33 - 120° F (1 - 50° C)

Electrical Characteristics:  120V/ 60 Hz, 35 Watts
The Culligan® Medallist Plus Sulfur-OX3™ water filter system has been tested and certified by 

WQA against NSF/ANSI Standard 372, CSA B483.1, and NSF/ANSI Standard 42 for the effective 

reduction of hydrogen sulfide up to 500 gallons as verified and substantiated by test data.
The Culligan® Outdoor Medallist Plus Sulfer-OX3™ water filter system has been tested and 

certified by WQA against NSF/ANSI Standard 372 and Standard NSF/ANSI 42 for the effective 

reduction of hydrogen sulfide up to 500 gallons as verified and substantiated by test data.
For installations in Massachusetts, the Massachusetts Plumbing Code 248 CMR shall be adhered 

to. Consult your licensed plumber for installation of this system. This system and it’s installation must 

comply with state and local regulations. The use of saddle valves is not permitted.
Performance Indicator: If water flow decreases or a noticeable taste change occurs, the filter should be 

reconditioned. If conditions do not improve, contact your local Culligan Man. He can determine if your 

filter requires servicing. Do not use with water that is microbiologically unsafe or of unknown quality 

without adequate disinfection before or after the system.
Reconditioning cycle Frequency:  

Reconditioning frequency is recommended every three days but can vary with local water conditions.
Refer to the Installation and Operation Instructions, Parts List and Printed Warranties for more 

specific product information. To avoid contamination from improper handling and installation, your 

system should only be installed and serviced by your Culligan Man. Performance will vary based on 

local water conditions. The substances reduced by this product are not necessarily in your water.

Buyer Signature  _______________________     Date  ____________ 
Seller Signature  _______________________     Date  ____________ 

Содержание Medallist Plus Sulfur-OX3

Страница 1: ...Culligan Medallist Plus Sulfur OX3 Automatic Water Filter Owners Guide 01035157_C DCO 200348 10 20 ...

Страница 2: ...his Manual 4 Thank You 5 Specifications 6 Application 7 Operation 8 Programming 9 Error Codes 11 When How to Bypass Your Water Filter 13 Things to Check Before You Call For Service 14 Care and Cleaning of Your Water Filter 15 Performance Data Sheet 16 Records and Data 17 Culligan Limited Warranty 18 ...

Страница 3: ...ce or knowledge unless they have been given supervision or instruction CAUTION Children should be instructed not to play with this appliance CAUTION If the power cord from the power supply to the unit looks or becomes damaged the cord and power supply should be replaced by a Culligan Service Agent or similarly qualified person in order to avoid a hazard CAUTION To reduce the risk of fire use only ...

Страница 4: ...For example CAUTION Disassembly while under water pressure can result in flooding Warning Warning is used to indicate a hazard which could cause injury or death if ignored For example WARNING Electrical shock hazard Unplug the unit before removing the timer mechanism or cover plates The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur It m...

Страница 5: ...ot use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system CAUTION This system is to be supplied with cold water only Installation or maintenance done on this system by an untrained service person can cause major damage to equipment or property damage Not adhering to the recommended service maintenance can cause damage to equip...

Страница 6: ... 60 psi Operating Temperature 33 120 F 1 48 C Electrical Requirements 28 Volts 50 60 Hz Power Consumption Continuous Maximum 3 Watts 21 6 Watts Drain Flow 5 5 gpm Reconditioning Time Backwash 15 minutes Air Draw 40 minutes Fast Rinse 5 minutes Capacity based on 4 gpm and 3 mg l of Hydrogen Sulfide Measure from top of media bed to top of inlet fitting Not recommended for iron removal Max flow rates...

Страница 7: ...s microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit Pressure Although the system is designed and tested to operate at a maximum pressure of 60 psi it is not expected that the system should be exposed to such pressure for extended operation Culligan recommends following the IAPMO Uniform Plumbing code section 806 2 by installing a Press...

Страница 8: ...ect the programmed settings from tampering by unauthorized individuals When the lockout feature is activated the only parameters which can be adjusted are the Time of Day and the Time of Reconditioning Cycle Refer to the Setting of the Microprocessor for activating this feature Power Loss The AccuSoft circuit board is equipped with a Hi Cap Capacitor and EEPROM memory chip The capacitor is capable...

Страница 9: ...vice mode by holding the key for 5 seconds Delay Immediate Toggle Delay or Immediate Delay Locks in a regen signal after a 3 hour or more power outage regen can be set to go immediate or delay until the tor Only accessible from service mode time of day display by pressing and holding for 5 seconds not in programming menu Lock Unlock Toggle Lock Unlock Unlock Lock or unlock access to make program c...

Страница 10: ...n The display will first show tor for two seconds After tor is shown the display will then show the default of 2 00 AM or the current programmed time of reconditioning if already set The time can be adjusted in 30 minute increments by pressing the or keys Pressing the Status key will save the setting and move to the next programming step Reconditioning Cycle Interval This setting is used to set th...

Страница 11: ...r charge before returning the filter to the SERVICE position The display will show Fr in the left most digits and then the cycle time in the right most digits Adjust the value with the or keys Pressing the Status key will save the setting and move to the next programming step The Fast Rinse Time for the Sulfur OX3 filter system is 5 minutes Blank Display After the last programming menu is displaye...

Страница 12: ... hours the reconditioning cycle will begin as soon as the control completes the homing cycle Pressing the Status key will save the setting and go to the next Hidden Menu set Screen Locking This setting is used to lock out the user from changing most of the program menu settings When the Loc setting is saved the only program menus that can be changed are tod and tor The program menu settings will a...

Страница 13: ...ulligan water filters is a Cul Flo Valv Bypass To bypass unit simply turn the blue knob clockwise To return to filtered water service reverse the procedure turn the blue knob counter clockwise To BYPASS turn the blue knob clockwise see directional arrow on end of knob until the knob stops as shown DO NOT OVERTIGHTEN To return to SERVICE turn the blue knob counter clockwise see directional arrow on...

Страница 14: ...sure your water supply is work ing Open a tap ahead of the filter outside tap to see if you have any water pressure If you have water pressure check the bypass valve If it is in the Service position put it into the bypass and call your Culligan dealer for service Increased Usage Guests family additions new water using appliances etc all will result in more water usage and will require more capacit...

Страница 15: ...filters are sold for use on potable water only If at any time the water becomes contaminated such as during a boil water situation the operation of the water filter should be discontinued until it is verified that the water is again potable To do this turn the knob on the bypass valve to the bypass position Then call your Culligan dealer to have your system sanitized before it is placed back into ...

Страница 16: ...t Plus Sulfur OX3 water filter system has been tested and certified by WQA against NSF ANSI Standard 372 CSA B483 1 and NSF ANSI Standard 42 for the effective reduction of hydrogen sulfide up to 500 gallons as verified and substantiated by test data The Culligan Outdoor Medallist Plus Sulfer OX3 water filter system has been tested and certified by WQA against NSF ANSI Standard 372 and Standard NSF...

Страница 17: ..._______________ Settings Time of Recharge _____________ a m ________________ p m Reconditioning cycle Interval __________ days Time Clock Back Up tcb Gallons to signal _________________ gallons capacity CAPG Number of people in household _________ Water Analysis Total Hardness ___________________ gpg Total Iron ______________________ ppm Hydrogen Sulfide level _______________ pH acidity __________...

Страница 18: ...mplied warranties including without limitation warranties of merchantability and fitness for particular purpose to the extent required by law any such implied warranties are limited in duration to the one year period specified above for the entire conditioner As a manufacturer we do not know the characteristics of your water supply or the purpose for which you are purchasing a water filter The qua...

Страница 19: ...19 Notes 01035157 C 10 20 ...