The timer uses four buttons:
Button
Description
Set-up / Enter Key (Status) Advance timer through display options
Reconditioning Cycle Key
(REGEN)
Initiate a reconditioning cycle
Toggle Down Key (“-”)
Decrease the setting
Toggle Up Key (“+”)
Increase the setting
Time of Day
This setting is used to program the current time of day.
When in this step, the display will first show “tod” for two seconds.
After “tod” is displayed, “12:00 PM” will display
(or the current set time if already programmed) and the minutes will flash.
• The minutes are adjusted with the “+” or “-” key until the correct
value is displayed.
• Press the “Regen” key to flash the hours.
Adjust with the “+” or “-” key until the correct time is displayed.
Pressing the “Status” key will move to the next programming step.
Pressing “Regen” will move back to the minutes adjust.
Time of Reconditioning Cycle
This setting is used to program the time at which a reconditioning
cycle is to occur in the delay mode, or in immediate mode with time
clock backup on. The display will first show “tor” for two seconds.
After “tor” is shown the display will then show the default of 2:00 AM
(or the current programmed time of reconditioning if already set).
The time can be adjusted in 30 minute increments by pressing the
“+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step.
Reconditioning Cycle Interval
This setting is used to set the days between reconditioning in
time clock mode. The display will show “REG” icon and “tcb” for
two seconds and then display the numbers to change. Adjust the
value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next
programming step. The reconditioning cycle interval is 3 days for the
Sulfur-OX3 filter system.
Backwash Time
This setting is used to program the cycle 1 backwash time. The time
of the cycle is displayed in minutes. The display will show “buu” in
the display for two seconds and then the cycle time in the right most
digits. Adjust the value with the “+” or “-” keys. The backwash cycle
time for Sulfur-OX3 filter system is 15 minutes.
Pressing the “Status” key will save the setting and move
to the next programming step.
10