Last Revised 05/09/2013
58
Power Timer Restrictions
1.
User can perform a timed startup and shutdown for the PTZ.
2.
The time period between the startup and shutdown time is the operating
period, whereas the time period between the shutdown time and the startup
time is the shutdown period.
3.
The system will wake up once the controlled command is received. If no
controlled command is received within 60 seconds under non-menu status, the
PTZ re-enters the shutdown status.
4.
The priority of Assignment is higher than the Power Timer. That means that
the Assignment will be executed first whether or not the Power Times status is
in Startup or Shutdown status and the Power Timer can only be entered after
the Assignment has been completed. However other non-Assignment
functions would be automatically discontinued or quitted before the Power
Timer is executed.
POWER OFF SETUP < HOUR MINUTE SECOND >
This sets the power off time on 24 hour clock.
MODE OFF / EACHDAY / WORKDAY /
WEEKEND / MON ~ SUN
This switches the Power Timer option off and
on.
POWER ON SETUP < HOUR MINUTE
SECOND >
This sets the power on time on 24 hour clock.