EM00136493
rev. 1.0 EN
10
Paragraph 7 – Flow Rate Calibration
Programming
Operation
On the main menu appears the memorized cc/stroke value.
You can perform the calibration in two modes:
MANUAL – insert manually the cc/stroke value using the
key and then confirm with the
key.
AUTOMATIC – the pump runs 100 strokes, which are
started by pressing the
key, and at the end of the
strokes insert the amount aspirated by the pump using the
key and confirm with the
key.
The data entered will be used for the calculation of the flow
rates.
Paragraph 8 – Statistics
Programming
Operation
On the main menu is displayed, in hours, the operating time
of the pump; press
to access other statistics:
- Strokes = the number of strokes performed by the pump
- Q.ta (L) = the quantity dosed from the pump expressed in
liters; this information is calculated based on the memorized
cc/stroke value
- Power = the number of pump activations
- Reset = press
to reset the counters, select (YES) or
(NO), then press
to confirm.
Press
to return to the main menu.