Alarms
Dislay
Cause
Remedy
Alarm LED on
“Lev” icon flashing
End level alarm, without pump
operation interruption.
Restore the liquid level.
Alarm LED on
“Lev” and “Stop” icons flashing
End level alarm,
with pump
operation interruption.
Restore the liquid level.
Alarm LED on
“Flw” icon flashing
Flow alarm activated, the pump has
not received from the flow sensor
the programmed number of signals.
Press the
key.
“OFA” icon flashing
“Stop” icon flashing
O.F.A. alarm
Press the
key to stop the
flashing of the “Stop” icon, press
the key again to restart the pump.
“Alm” icon flashing
The value read by the probe is out
of the alarm band set
Check the "Alarm Band" parameter
for
the correct settings
in
programming mode.
“Cal” icon flashing
Probe not calibrated alarm
Perform the probe
calibration
procedure.