11
More
The more menu enables selection of the Timecode reader, Timecode generator,
Tone Loop, 2Wire listen and Cable Test.
More/Read Timecode
This option reads linear timecode at 24, 25, 29.97 and 30 frames per second using
the Ana in L XLR. The timecode is also output through the Ana XLR outputs so it may
be used as an ‘in line’ check. If the drop frame flag is set in the timecode stream then
‘DF’ will be displayed at the end of the time readout. The reader will resolve
timecode down to a level of -30dBu. The timecode may be monitored and metered,
the meter will follow whichever type has been selected in ‘setup/ ana meter’. (PPM
or VU).
More Read Timecode
Freeze
Press select while this is highlighted to
freeze the timecode display. When
selected it will change to read. Select
again to restart the display
More Read Timecode
nnFPS
This selects the frame rate range for the
reader. Set to 25FPS for 24 or 25FPS or
30FPS for 29.97 (dropframe) or 30FPS.
More/Generate Timecode
This generates test linear timecode at 24, 25, 29.97 (dropframe) and 30 frames per
second using the Ana out L XLR. Level is set at 0dBu.
More Generate Timecode Start
Press select while this is highlighted to
start timecode generation. Generation
will start at the time displayed. When
started the display will change to ‘Freeze’. Select again to stop the timecode.
Timecode continues to be generated at the frozen time.
More Generate Timecode Clear
This will set the timecode generated to
00:00:00:00.
Содержание dBbox3
Страница 1: ...1 dBbox3 the manual version 4 firmware ...