17
Levels
All dB references in this manual relate to the following:
The dBbox3 ‘0dB’ output level is 0dBu, that is it generates 0.775 volts into a 10k ohm
load, the most common input impedance these days. Into a 600 ohm load it will be
approximately 0.3dB lower. The dBbox3 balanced analogue output impedance is 75
ohms. Inevitably the dBbox3 will sometimes be plugged into a source with phantom
power or something unpleasant on the line and the unit must be able to protect
itself. This protection comes at a price which includes a slightly higher output
impedance in order to overcome these possibilities, hence the variation.
If you have any firmware problems with your dBbox3 or you spot any incorrect
details in our manual please let us know so we can correct. Thank you.
Specifications.
Analogue and AES/SPDIF combined.
Input metering –
accurate to -0.2dB or one display segment.
Ref. 0dBu
125Hz – 20kHz
accurate to 1dB or one display segment.
50Hz – 20kHz
Output levels –
accurate to -0.2dB 50Hz – 15kHz
Ref. 0dBu
accurate to -0.4dB 50Hz – 20kHz
Normally -0.1dB at 1kHz.
Phantom power measurement- +- 1 volt.
dBbox2 and dBbox3 firmware is the intellectual property and copyright of CTP
Systems in the UK ©2014-2021
Содержание dBbox3