EN
EN • 9
ERROR lAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the batterys
positive pole?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in
or
?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
TEMPERATURE SENSOR
Activated temperature sensor will be indicated by a lit temperature sensor
indicator lamp. The temperature sensor will adjust the voltage to the
ambient temperature. Place the temperature sensor in the positive clamp
or as the close to the battery as possible.
POWER lAMP
If the power lamp is lit with a:
SUPPLY
NORMAL
RECOND
RECOND
SUPPLY
MODE
1. STEADY lIGHT
The mains cable is connected to the wall socket.
2. FlASHING lIGHT:
The charger has entered the energy save mode. This happens if the
charger isn´t connected to the battery in 2 minutes.
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds
the charger activates the selected program. The selected program will be
restarted next time the charger is connected.
The table explains the different Charging Programs:
Program
Battery
Size (Ah)
Explanation
Temp range
NORMAL
40–500Ah
Normal battery program
14.4V/25A. Use for WET batteries,
Ca/Ca, MF and for most GEL batteries
(-4°F–122°F)
-20°C–+50°C
RECOND
40–500Ah
Recond program
15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds
the Recond step to the normal battery
program.
(-4°F–122°F)
-20°C–+50°C
40–500Ah
Supply program
13.6V/25A
Use as 12V power supply or use for
float maintenance charging when
100% capacity of the battery is
required. Supply program activates
Float step without time or voltage
limitation.
(-4°F–122°F)
-20°C–+50°C
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
20021718A Multi US 25000MXS 25EC NA, Manual, Insert pages, Print file_003.indd 9
2015-02-12 15:54:08