5 - FILLING :
Go to filling tank menu from maintenance screen.
Select product to fill
Connect a suction pipe on the external suction connector
Start the engine of the Gecko (if necessary).
Press “
VALIDATE
” to start filling
[1]
.
[
1
]
[
2
]
The system automatically primes (mini 5s) and then fills the required tank.
You can press “
CANCEL
” key
[2]
to stop the filling.
→
If you wish to continue, press “
NO
”.
→
To resume filling, press “
VALIDATE
” key
[1]
.
→
If you want to stop, press “
YES
”.
After stopping, the system automatically flushing itself.
Press «
EXIT
» to exit.
NB : Filling stops automatically when the tank is full.
6 - AUTONOMY :
If the option is selected, the system calculates the remaining autonomy while the product
is being measured out.
Autonomy is displayed in minutes under the tank of product used.
This autonomy is calculated according to the level of product remaining in the tank and
the product proportioning flow rate.
If less than 2 minutes of autonomy are left, display of autonomy disappears and the mes-
sage “TIME REMAINING < 2 MIN” flashes on the right of the level in the water tank.
=> Prepare to switch to an external product source if possible.
Foam concentrate
filling
Additive
filling
Intervention procedure
Содержание Iguane 120-30
Страница 1: ...Version 1 21 01 16 Fire fighting IGUANE Range USER MANUAL IGUANE 120 30...
Страница 2: ...2...
Страница 5: ...5 PRESENTATION OF THE IGUANE...
Страница 8: ...8 HYDRAULIC DRAWING...
Страница 10: ...10 INTERVENTION PROCEDURE...
Страница 21: ...21 ANNEXES...
Страница 22: ...22 Motor OMR80 Option...
Страница 28: ...28 PURGE OF THE FILTER CAMELEON Open the valve of the suction filter Filter valve Cameleon...